MC-1 Manual Control Station – Deluge & Preaction Valves and Components | Tyco Fire

Global Directory

  • HVAC Equipment
    • Johnson ControlsJCI logo
    • YorkYORK logo
    • HitachiHitachi
    • LuxaireLuxaire Heating & Cooling logo
    • Championchampion
    • QuantechQuantech logo
    • ColemanColeman logo
    • RuskinRuskin logo
    • EnvirotecEnviro-Tec logo
    • TempmasterTempMaster logo
    • AirMateAir Mate Logo
    • AMPCOAnsul logo
    • TrionTrion IAQ logo
    • TriatekTriatek logo
  • Security
    • American DynamicsTyco American Dynamics logo
    • Bentel SecurityTyco Bentel Security logo
    • CEM SystemsTyco CEM Systems logo
    • DSCTyco DSC logo
    • ExacqTyco Exacq logo
    • IllustraTyco Illustra logo
    • KantechTyco Kantech logo
    • Software HouseTyco Software House logo
  • Digital Solutions
    • Johnson ControlsJCI logo
  • Industrial Refrigeration
    • YorkYORK logo
    • FrickFrick Industrial Refrigeration logo
    • SabroeSabroe logo
  • Fire Suppression
    • tycoTyco Blue Logo
    • AnsulAnsul
    • ChemguardChemguard logo
    • SkumSkum logo
    • HygoodHygood logo
    • GrinnellGrinell logo
    • SprinkCADSprinkCAD logo
    • Pyro ChemPyro-Chem logo
    • AquaMistAnsul logo
  • Retail Solutions
    • Sensormatic
    • ShopperTrakShopperTrak
    • TrueVueTrueVUE logo
  • Residential and Smart Home
    • Johnson ControlsJCI logo
    • LUXLUX logo
  • Building Automation & Controls
    • Johnson ControlsJCI logo
    • MetasysMetasys logo
    • PENNPenn logo
    • Facility ExplorerFacility Explorer logo
    • VerasysVerasys logo
    • BCPROAnsul logo
  • Fire Detection
    • AutocallAnsul logo
    • FireClassFireClass logo
    • SimplexSimplex logo
    • VigilantVigilant logo
    • ZettlerZettler logo
    • DBEDBE written on a white background
  • Distributed Energy Storage
    • Johnson ControlsJCI logo
JohnsonControls logo
  • Products & Solutions
    Products & Solutions
    • Sprinklers, Nozzles & Accessories
    • Valves, Devices, & Components
    • Fire Grooved
    • Corrosion Solutions
    • Antifreeze
    • Flexible Hose Assemblies and Components
    • MLC-S Pipe System
    • Performance Based Design
    • Smart Prefabricated Solutions
  • Services and Support
    Services and Support
    • Design Services
      Design Services
      • Design Services
      • CAD Files
      • Revit Files
      • Fluid Delivery Time (FDT) Calculation Request Form
    • Training
  • Resources
    Resources
    • Resources Library
    • Technical Datasheets
    • Tech Data Update Summaries
    • Global Fire Sprinkler Guide
    • Regional Product Catalogs
    • Americas Price Book
    • Terms and Conditions
  • Insights
Search Contact Us

Search

Clear
SearchLoading
  1. Tyco-Fire
  2. Products and Solutions
  3. Valves, Devices, and Components
  4. Deluge and Preaction Valves and Components
  5. MC-1 Manual Control Station
Product Image_MC-1_2
Product Image_MC-1_3
  • Thumb Image_MC-1_2.png
  • Thumb Image_MC-1_3.png

MC-1 Manual Control Station

For deluge and preaction systems

System and Actuation Type For use with deluge or preaction systems
Listings and Approvals UL and C-UL Listed; FM Approved
Back to Top

DV-5A Pretrim Deluge Valve

  • Overview
  • Features & Benefits
  • Related Products
  • Specifications
  • Technical Resources
Contact Us

Tamper-resistant emergency release

The Tyco® Model MC-1 (MC-2) manual control station provides a tamper-resistant means for emergency release of Tyco® automatic water control valves. Interconnection with the valves may be direct via a hydraulic (wet) pilot line or indirect via a pneumatic (dry) pilot line to a Model DP-1 dry pilot actuator. The MC-2 manual control station is a modified MC-1 designed for use as a trim component for the Model DV-5A automatic water control valve.
Tamper-resistant emergency release

Features

  • Valve interconnection can be direct via a hydraulic (wet) pilot line or indirect via a pneumatic (dry) pilot line to a Model DP-1 dry pilot actuator
  • MC-2 is a modified version of the MC-1 used as a DV-5A automatic water control valve trim component
  • UL and C-UL Listed, FM Approved
  • Operating instructions are imprinted on the cover
  • For vertical installation (so cover will fall open when break rod is not in place)

Benefits

Industry-Leading Warranty
Industry-Leading Warranty

Johnson Controls stands behind its products with a unique warranty. See our Terms and Conditions for details. 

Trusted Performance
Trusted Performance

Tyco® products have helped to protect spaces for more than 130 years. 

Broad Portfolio
Broad Portfolio

Tyco® products are part of a time-tested, broad portfolio of fire protection solutions, including fire grooved, sprinklers, valves, water mist, foam concentrates and hardware, and much more.

Related Products

DV-5A Pretrim Deluge Valve

DV-5A Pretrim Deluge Valve

DV-5A Pretrim Preaction Valve

DV-5A Pretrim Preaction Valve

DP-1 Dry Pilot Actuator

DP-1 Dry Pilot Actuator

MRA-1 Manual Reset Actuator

MRA-1 Manual Reset Actuator

Technical Specification

Listings and Approvals UL and C-UL Listed; FM Approved Minimum Ambient Temperature Dry Pilot Lines: −50°F (−46°C) Wet Pilot Lines: 40°F (4°C)
Pressure Rating 20 to 300 psi (1,4 to 20,7 bar) System and Actuation Type For use with deluge or preaction systems

Technical Resources

Document Name
Description
Language
Resource Type

Data Sheet

TFP1382 Technical Data Sheet  (English)

MC-1 Manual Control Station - TFP1382 (English) For Deluge And Preaction Systems Manual Release Service

English Data Sheet
VIEW

Brochure

Tyco-Fire-Valves-System-Components (English)

Fire Valves and System Components

English Brochure
VIEW

Data Sheet

TFP1382_ES Technical Data Sheet – Spanish Translation  (Spanish)

MC-1 Manual Control Station - TFP1382 (Spanish) For Deluge And Preaction Systems Manual Release Service

Spanish Data Sheet
VIEW

Data Sheet

TFP1382_DE Technical Data Sheet – German Translation  (German)

MC-1 Manual Control Station - TFP1382 (German) For Deluge And Preaction Systems Manual Release Service

German Data Sheet
VIEW

Data Sheet

TFP1382_SV Technical Data Sheet – Swedish Translation (Swedish-Sweden)

MC-1 Manual Control Station - TFP1382 (Swedish) For Deluge And Preaction Systems Manual Release Service

Swedish-Sweden Data Sheet
VIEW

Data Sheet

TFP1382_FR Technical Data Sheet – French Translation  (French)

MC-1 Manual Control Station - TFP1382 (French) For Deluge And Preaction Systems Manual Release Service

French Data Sheet
VIEW

Data Sheet

TFP1382_CS Technical Data Sheet – Czech Translation  (Czech)

MC-1 Manual Control Station - TFP1382 (Czech) For Deluge And Preaction Systems Manual Release Service

Czech Data Sheet
VIEW

Data Sheet

TFP1382 HU Technical Data Sheet – Hungarian Translation 

MC-1 Manual Control Station - TFP1382 (Hungarian) For Deluge And Preaction Systems Manual Release Service

Data Sheet
VIEW

Data Sheet

TFP1382_IT Technical Data Sheet – Italian Translation  (Italian-Italy)

MC-1 Manual Control Station - TFP1382 (Italian) For Deluge And Preaction Systems Manual Release Service

Italian-Italy Data Sheet
VIEW

Data Sheet

TFP1382_NL Technical Data Sheet – Dutch Translation  (Flemish-Belgium)

MC-1 Manual Control Station - TFP1382 (Dutch) For Deluge And Preaction Systems Manual Release Service

Flemish-Belgium Data Sheet
VIEW

Data Sheet

TFP1382_NO Technical Data Sheet – Norwegian Translation  (Norwegian (Bokmal)-Norway)

MC-1 Manual Control Station - TFP1382 (Norwegian) For Deluge And Preaction Systems Manual Release Service

Norwegian (Bokmal)-Norway Data Sheet
VIEW

Data Sheet

TFP1382_PL Technical Data Sheet – Polish Translation 

MC-1 Manual Control Station - TFP1382 (Polish) For Deluge And Preaction Systems Manual Release Service

Data Sheet
VIEW

Data Sheet

TFP1382_PT Technical Data Sheet – Portuguese Translation  (Portuguese-Brazil)

MC-1 Manual Control Station - TFP1382 (Portuguese) For Deluge And Preaction Systems Manual Release Service

Portuguese-Brazil Data Sheet
VIEW

Data Sheet

TFP1382_RU Technical Data Sheet – Russian Translation  (Russian-Russia)

MC-1 Manual Control Station - TFP1382 (Russian) For Deluge And Preaction Systems Manual Release Service

Russian-Russia Data Sheet
VIEW
No resource found for selected filter

Back

Next

Looking for more Resources
A laptop on a desk with a finger pointing at a screen

SprinkCAD Software Suite 

Save time and ensure quality with the SprinkCAD software suite. Developed to offer fire sprinkler system designers a powerful set of digital tools to create precise solutions. 

Learn about our all-in-one software package
Contact Us
  • Antifreeze
  • Corrosion Solutions
  • CPVC
  • Fire Grooved
  • Flexible Hose Assemblies and Components
  • MLC-S Pipe System
  • Performance Based Design
  • Sprinklers, Nozzles and Accessories
  • Valves, Devices, and Components
  • Technical Datasheets
  • Design Files
  • Tech Data Update Summaries
  • Regional Product Catalogs
  • Americas Price Book
  • Insights
  • WARNING: Cancer & Reproductive Harm
  • Regulatory & Health Warnings
  • SVHC statement - CPVC products containing UV-238
Tyco logo
Connect With Us
  • LinkedIn logo
  • Twitter X logo
  • YouTube Play logo
Johnson Controls logo
© 2025 Johnson Controls. All Rights Reserved.
  • JohnsonControls.com
  • Privacy
  • Legal
  • Terms and Conditions
  • Cookie Preferences