QRS-2 Quick Release Switch | Tyco Fire

Global Directory

  • HVAC Equipment
    • Johnson ControlsJCI logo
    • YorkYORK logo
    • HitachiHitachi
    • LuxaireLuxaire Heating & Cooling logo
    • Championchampion
    • QuantechQuantech logo
    • ColemanColeman logo
    • RuskinRuskin logo
    • EnvirotecEnviro-Tec logo
    • TempmasterTempMaster logo
    • AirMateAir Mate Logo
    • AMPCOAnsul logo
    • TrionTrion IAQ logo
    • TriatekTriatek logo
  • Security
    • American DynamicsTyco American Dynamics logo
    • Bentel SecurityTyco Bentel Security logo
    • CEM SystemsTyco CEM Systems logo
    • DSCTyco DSC logo
    • ExacqTyco Exacq logo
    • IllustraTyco Illustra logo
    • KantechTyco Kantech logo
    • Software HouseTyco Software House logo
  • Digital Solutions
    • Johnson ControlsJCI logo
  • Industrial Refrigeration
    • YorkYORK logo
    • FrickFrick Industrial Refrigeration logo
    • SabroeSabroe logo
  • Fire Suppression
    • tycoTyco Blue Logo
    • AnsulAnsul
    • ChemguardChemguard logo
    • SkumSkum logo
    • HygoodHygood logo
    • GrinnellGrinell logo
    • SprinkCADSprinkCAD logo
    • Pyro ChemPyro-Chem logo
    • AquaMistAnsul logo
  • Retail Solutions
    • Sensormatic
    • ShopperTrakShopperTrak
    • TrueVueTrueVUE logo
  • Residential and Smart Home
    • Johnson ControlsJCI logo
    • LUXLUX logo
  • Building Automation & Controls
    • Johnson ControlsJCI logo
    • MetasysMetasys logo
    • PENNPenn logo
    • Facility ExplorerFacility Explorer logo
    • VerasysVerasys logo
    • BCPROAnsul logo
  • Fire Detection
    • AutocallAnsul logo
    • FireClassFireClass logo
    • SimplexSimplex logo
    • VigilantVigilant logo
    • ZettlerZettler logo
    • DBEDBE written on a white background
  • Distributed Energy Storage
    • Johnson ControlsJCI logo
JohnsonControls logo
  • Products & Solutions
    Products & Solutions
    • Sprinklers, Nozzles & Accessories
    • Valves, Devices, & Components
    • Fire Grooved
    • Corrosion Solutions
    • Antifreeze
    • Flexible Hose Assemblies and Components
    • MLC-S Pipe System
    • Performance Based Design
    • Smart Prefabricated Solutions
  • Services and Support
    Services and Support
    • Design Services
      Design Services
      • Design Services
      • CAD Files
      • Revit Files
      • Fluid Delivery Time (FDT) Calculation Request Form
    • Training
  • Resources
    Resources
    • Resources Library
    • Technical Datasheets
    • Tech Data Update Summaries
    • Global Fire Sprinkler Guide
    • Regional Product Catalogs
    • Americas Price Book
    • Terms and Conditions
  • Insights
Search Contact Us

Search

Clear
SearchLoading
  1. Tyco-Fire
  2. Products and Solutions
  3. Valves, Devices, and Components
  4. Accelerators
  5. QRS-2 Quick Release Switch
Product image_QRS_2
  • Thumb image_QRS_2

QRS-2 Quick Release Switch

Electronic accelerator for dry pipe or preaction sprinkler systems

The Tyco® QRS-2 Quick Release Switch helps reduce valve operating time and false trip issues that often occur with traditional mechanical accelerators.

  • Operation of Tyco DPV-1 dry pipe or DV-5A preaction valve within four seconds
  • Ideal to retrofit existing mechanical accelerators where a releasing panel is already installed
  • UL Listed and FM Approved
Back to Top

QRS-2 Quick Release Switch

  • Overview
  • Features
  • Benefits
  • Technical Resources
  • Related Products

Reduce Water Delivery Times

The QRS-2 is a quick-opening device intended to reduce the operating time of a dry pipe valve in a dry pipe system or an automatic control valve (deluge valve) in a double-interlock electric/electric preaction system. The QRS-2 electronic dry pipe accelerator automatically adjusts to both small and slow changes in system pressure, but it trips with a steady drop in pressure.
Reduce Water Delivery Times

Features

  • Operation of Tyco DPV-1 dry pipe or DV-5A preaction valve within four seconds
  • Ideal to retrofit existing mechanical accelerators where a releasing panel is already installed
  • UL Listed and FM Approved
  • Proven electric release technology as used for electrically operated deluge and preaction systems
  • Control up to two QRS-2 switches on one to two system risers (Tyco Model DPV-1 Valve with AutoPulse Z-10 or AutoPulse Z-20 Releasing Panel)
  • Control up to four QRS-2 switches on one to four system risers (Tyco Model DPV-1 Valve with Potter PFC-4410G3 or PFC-4410RC releasing panel)
  • Built-in low and high pressure alarm supervision
  • Integrated indicator light shows system status

Benefits

Faster Trip Time
Faster Trip Time

Deliver water sooner with a quicker, more consistent trip time compared to a mechanical accelerator.

Reduce False Trips
Reduce False Trips

Active air pressure monitoring adjusts to small and slow changes in pressure system, but trips when there is a steady pressure drop.

Easy Resetting
Easy Resetting

Electronic reset eliminates the complicated breakdown, overhaul, and reassembly of a mechanical accelerator.

Technical Resources

Document Name
Description
Language
Resource Type

Data Sheet

TFP1120 Technical Data Sheet (English)

QRS-2 Quick Release Switch – TFP1120 (English)

English Data Sheet
VIEW

Data Sheet

TFP1121 Technical Data Sheet (English)

Model QRS-2 Quick Release Switch – Electronic Accelerator for Prescient III Gas Suppression Panel

English Data Sheet
VIEW

Data Sheet

TFP1122 Technical Data Sheet (English)

Model QRS-2 Quick Release Switch – Electronic Accelerator for Potter 4410G3 Releasing Control Panel

English Data Sheet
VIEW

Data Sheet

TFP1123 Technical Data Sheet (English)

Model QRS-2 Quick Release Switch – Electronic Accelerator for AutoPulse Z-10 Release Control Panel

English Data Sheet
VIEW

Data Sheet

TFP1124 Technical Data Sheet (English)

Model QRS-2 Quick Release Switch – Electronic Accelerator for AutoPulse Z-20 Release Control Panel

English Data Sheet
VIEW

Video

DPV-1 Dry Pipe Actuation (English)

Overview of DPV-1 System Actuation with an Accelerator

English Video
VIEW

Video

DV-5A Preaction Actuation (English)

Overview of DV-5A Preaction and Quell System Actuation

English Video
VIEW

Flyer

QRS-2 Quick Release Switch (English)

Product overview flyer

English Flyer
VIEW

Brochure

Preaction System Components (English)

Overview of DV-5A valve and key preaction trim components, as well as NG-2 nitrogen generators to avoid corrosion issues

English Brochure
VIEW
No resource found for selected filter

Back

Next

Looking for more Resources

Related Products

Vizor Electronic Dry Pipe Accelerator

Vizor Electronic Dry Pipe Accelerator

DPV-1 Pre-trim Dry Pipe Valve

DPV-1 Pre-trim Dry Pipe Valve

DV-5A Pretrim Deluge Valve

DV-5A Pretrim Deluge Valve

DV-5A Pretrim Preaction Valve

DV-5A Pretrim Preaction Valve

A laptop on a desk with a finger pointing at a screen

SprinkCAD Software Suite 

Save time and ensure quality with the SprinkCAD software suite. Developed to offer fire sprinkler system designers a powerful set of digital tools to create precise solutions. 

Learn about our all-in-one software package
Contact Us
  • Antifreeze
  • Corrosion Solutions
  • CPVC
  • Fire Grooved
  • Flexible Hose Assemblies and Components
  • MLC-S Pipe System
  • Performance Based Design
  • Sprinklers, Nozzles and Accessories
  • Valves, Devices, and Components
  • Technical Datasheets
  • Design Files
  • Tech Data Update Summaries
  • Regional Product Catalogs
  • Americas Price Book
  • Insights
  • WARNING: Cancer & Reproductive Harm
  • Regulatory & Health Warnings
  • SVHC statement - CPVC products containing UV-238
Tyco logo
Connect With Us
  • LinkedIn logo
  • Twitter X logo
  • YouTube Play logo
Johnson Controls logo
© 2025 Johnson Controls. All Rights Reserved.
  • JohnsonControls.com
  • Privacy
  • Legal
  • Terms and Conditions
  • Cookie Preferences