Model K17-231 Sprinkler – Sprinklers, Nozzles & Accessories | Tyco Fire

Global Directory

  • HVAC Equipment
    • Johnson ControlsJCI logo
    • YorkYORK logo
    • HitachiHitachi
    • LuxaireLuxaire Heating & Cooling logo
    • Championchampion
    • QuantechQuantech logo
    • ColemanColeman logo
    • RuskinRuskin logo
    • EnvirotecEnviro-Tec logo
    • TempmasterTempMaster logo
    • AirMateAir Mate Logo
    • AMPCOAnsul logo
    • TrionTrion IAQ logo
    • TriatekTriatek logo
  • Security
    • American DynamicsTyco American Dynamics logo
    • Bentel SecurityTyco Bentel Security logo
    • CEM SystemsTyco CEM Systems logo
    • DSCTyco DSC logo
    • ExacqTyco Exacq logo
    • IllustraTyco Illustra logo
    • KantechTyco Kantech logo
    • Software HouseTyco Software House logo
  • Digital Solutions
    • Johnson ControlsJCI logo
  • Industrial Refrigeration
    • YorkYORK logo
    • FrickFrick Industrial Refrigeration logo
    • SabroeSabroe logo
  • Fire Suppression
    • tycoTyco Blue Logo
    • AnsulAnsul
    • ChemguardChemguard logo
    • SkumSkum logo
    • HygoodHygood logo
    • GrinnellGrinell logo
    • SprinkCADSprinkCAD logo
    • Pyro ChemPyro-Chem logo
    • AquaMistAnsul logo
  • Retail Solutions
    • Sensormatic
    • ShopperTrakShopperTrak
    • TrueVueTrueVUE logo
  • Residential and Smart Home
    • Johnson ControlsJCI logo
    • LUXLUX logo
  • Building Automation & Controls
    • Johnson ControlsJCI logo
    • MetasysMetasys logo
    • PENNPenn logo
    • Facility ExplorerFacility Explorer logo
    • VerasysVerasys logo
    • BCPROAnsul logo
  • Fire Detection
    • AutocallAnsul logo
    • FireClassFireClass logo
    • SimplexSimplex logo
    • VigilantVigilant logo
    • ZettlerZettler logo
    • DBEDBE written on a white background
  • Distributed Energy Storage
    • Johnson ControlsJCI logo
JohnsonControls logo
  • Products & Solutions
    Products & Solutions
    • Sprinklers, Nozzles & Accessories
    • Valves, Devices, & Components
    • Fire Grooved
    • Corrosion Solutions
    • Antifreeze
    • Flexible Hose Assemblies and Components
    • MLC-S Pipe System
    • Performance Based Design
    • Smart Prefabricated Solutions
  • Services and Support
    Services and Support
    • Design Services
      Design Services
      • Design Services
      • CAD Files
      • Revit Files
      • Fluid Delivery Time (FDT) Calculation Request Form
    • Training
  • Resources
    Resources
    • Resources Library
    • Technical Datasheets
    • Tech Data Update Summaries
    • Global Fire Sprinkler Guide
    • Regional Product Catalogs
    • Americas Price Book
    • Terms and Conditions
  • Insights
Search Contact Us

Search

Clear
SearchLoading
  1. Tyco-Fire
  2. Products and Solutions
  3. Sprinklers, Nozzles, and Accessories
  4. Storage
  5. Model K17-231 Sprinkler
K17-231_FIS Product Image1
K17-231_FIS Product Image2
  • K17-231_FIS Thumb Image1
  • K17-231_FIS Thumb Image2

Model K17-231 Sprinkler

16.8 K-Factor Standard Response, Standard Coverage Upright and Pendent Sprinklers

Orientation Upright, Pendent
K-Factor 16.8
Temperature Rating Up to 286° F
Response Standard
Back to Top

Model K17-231 Sprinkler

  • Overview
  • Features & Benefits
  • Related Products
  • Specifications
  • Technical Resources
Contact Us

Ideal for High-Challenge Storage Occupancies

Looking to upgrade your storage sprinkler system? The Model K17-231 is a large-orifice, frangible bulb-type automatic fire protection sprinkler designed to perform well in high-challenge storage occupancies. The K17-231 is a 16.8 K-factor standard response, standard coverage, upright and pendent sprinkler. This sprinkler was subjected to full-scale, high-piled storage fire tests to qualify its use in lieu of 8.0 or 11.2 K-factor standard spray sprinklers for the protection of high-piled storage. The low-pressure requirement of the Model K17-231 (as low as 7 psi) can save you money by reducing branch line size — to take advantage of maximized spacing — and upgrading existing densities.
Ideal for High-Challenge Storage Occupancies

Features

  • Very large orifice
  • Low-pressure requirement (as low as 7 psi)
  • For 16.8 K-factor upright and pendent control mode density area sprinkler (TY7151, TY7251), see TFP332 for technical information and listing details
  • Produce a hemispherical water distribution pattern
  • UL and C-UL Listed, FM and NYC Approved

Benefits

Dependable
Dependable

Our fire protection systems help ensure that your property has the coverage you need—exactly when you need it.

Flexible
Flexible

Our storage options offer the flexibility needed to accommodate changing demands.

Trusted Performance
Trusted Performance

Tyco® products have helped to protect spaces for more than 130 years.

Related Products

Model ESFR-17 Sprinklers - Pendent

Model ESFR-17 Sprinklers - Pendent

Model ESFR-17 Sprinklers - Upright

Model ESFR-17 Sprinklers - Upright

Model LD Sprinkler

Model LD Sprinkler

Technical Specification

Hazard Storage Listings and Approvals UL and C-UL Listed; FM and NYC Approved
Note See Technical Data Sheet for details SIN Numbers TY7151, TY7251
Thread 3/4-inch Wrench W-Type 8

Technical Resources

Document Name
Description
Language
Resource Type

Data Sheet

TFP332 Technical Data Sheet (English)

K17-231 Sprinklers - TFP332 (English) Upright and Pendent, Standard Response, Standard Coverage, K-factor = 16.8

English Data Sheet
VIEW

Brochure

Tyco-Storage-Fire-Sprinkler-Applications_10-20 (English)

Fire Sprinkler Solutions for Storage Applications

English Brochure
VIEW

Video

10687-1-Storaga-Solutions-Update-100720-v2 (English)

TYCO® Storage Sprinkler Solutions

English Video
VIEW

Data Sheet

TFP332_ES Technical Data Sheet – Spanish Translation (Spanish)

K17-231 Sprinklers - TFP332 (Spanish) Upright and Pendent, Standard Response, Standard Coverage, K-factor = 16.8

Spanish Data Sheet
VIEW

Data Sheet

TFP332_DE Technical Data Sheet – German Translation (German)

K17-231 Sprinklers - TFP332 (German) Upright and Pendent, Standard Response, Standard Coverage, K-factor = 16.8

German Data Sheet
VIEW

Data Sheet

TFP332_SV Technical Data Sheet – Swedish Translation (Swedish-Sweden)

K17-231 Sprinklers - TFP332 (Swedish) Upright and Pendent, Standard Response, Standard Coverage, K-factor = 16.8

Swedish-Sweden Data Sheet
VIEW

Data Sheet

TFP332_FR Technical Data Sheet – French Translation (French)

K17-231 Sprinklers - TFP332 (French) Upright and Pendent, Standard Response, Standard Coverage, K-factor = 16.8

French Data Sheet
VIEW

Data Sheet

TFP332_CS Technical Data Sheet – Czech Translation (Czech)

K17-231 Sprinklers - TFP332 (Czech) Upright and Pendent, Standard Response, Standard Coverage, K-factor = 16.8

Czech Data Sheet
VIEW

Data Sheet

TFP332_HU Technical Data Sheet – Hungarian Translation

K17-231 Sprinklers - TFP332 (Hungarian) Upright and Pendent, Standard Response, Standard Coverage, K-factor = 16.8

Data Sheet
VIEW

Data Sheet

TFP332_IT Technical Data Sheet – Italian Translation (Italian-Italy)

K17-231 Sprinklers - TFP332 (Italian) Upright and Pendent, Standard Response, Standard Coverage, K-factor = 16.8

Italian-Italy Data Sheet
VIEW

Data Sheet

TFP332_NL Technical Data Sheet – Dutch Translation (Flemish-Belgium)

K17-231 Sprinklers - TFP332 (Dutch) Upright and Pendent, Standard Response, Standard Coverage, K-factor = 16.8

Flemish-Belgium Data Sheet
VIEW

Data Sheet

TFP332_NO Technical Data Sheet – Norwegian Translation (Norwegian (Bokmal)-Norway)

K17-231 Sprinklers - TFP332 (Norwegian) Upright and Pendent, Standard Response, Standard Coverage, K-factor = 16.8

Norwegian (Bokmal)-Norway Data Sheet
VIEW

Data Sheet

TFP332_PL Technical Data Sheet – Polish Translation

K17-231 Sprinklers - TFP332 (German) Upright and Pendent, Standard Response, Standard Coverage, K-factor = 16.8

Data Sheet
VIEW

Data Sheet

TFP332_PT Technical Data Sheet – Portuguese Translation (Portuguese-Brazil)

K17-231 Sprinklers - TFP332 (Portuguese) Upright and Pendent, Standard Response, Standard Coverage, K-factor = 16.8

Portuguese-Brazil Data Sheet
VIEW

Data Sheet

TFP332_RU Technical Data Sheet – Russian Translation (Russian-Russia)

K17-231 Sprinklers - TFP332 (Russian) Upright and Pendent, Standard Response, Standard Coverage, K-factor = 16.8

Russian-Russia Data Sheet
VIEW

Revit File

TY-7151-Imperial (English)

K17-231 - TY-7151 (Imperial)

English Revit File
VIEW

Revit File

TY-7251-Imperial (English)

K17-231 - TY-7251 (Imperial)

English Revit File
VIEW

Revit File

TY-7151-Metric (English)

K17-231 - TY-7151 (Metric)

English Revit File
VIEW

Revit File

TY-7251-Metric (English)

K17-231 - TY-7251 (Imperial)

English Revit File
VIEW
No resource found for selected filter

Back

Next

Looking for more Resources
A laptop on a desk with a finger pointing at a screen

SprinkCAD Software Suite 

Save time and ensure quality with the SprinkCAD software suite. Developed to offer fire sprinkler system designers a powerful set of digital tools to create precise solutions. 

Learn about our all-in-one software package
Contact Us
  • Antifreeze
  • Corrosion Solutions
  • CPVC
  • Fire Grooved
  • Flexible Hose Assemblies and Components
  • MLC-S Pipe System
  • Performance Based Design
  • Sprinklers, Nozzles and Accessories
  • Valves, Devices, and Components
  • Technical Datasheets
  • Design Files
  • Tech Data Update Summaries
  • Regional Product Catalogs
  • Americas Price Book
  • Insights
  • WARNING: Cancer & Reproductive Harm
  • Regulatory & Health Warnings
  • SVHC statement - CPVC products containing UV-238
Tyco logo
Connect With Us
  • LinkedIn logo
  • Twitter X logo
  • YouTube Play logo
Johnson Controls logo
© 2025 Johnson Controls. All Rights Reserved.
  • JohnsonControls.com
  • Privacy
  • Legal
  • Terms and Conditions
  • Cookie Preferences