DV-5A Deluge Red-E Cabinet – Deluge & Preaction Valves and Components | Tyco Fire

Global Directory

  • HVAC Equipment
    • Johnson ControlsJCI logo
    • YorkYORK logo
    • HitachiHitachi
    • LuxaireLuxaire Heating & Cooling logo
    • Championchampion
    • QuantechQuantech logo
    • ColemanColeman logo
    • RuskinRuskin logo
    • EnvirotecEnviro-Tec logo
    • TempmasterTempMaster logo
    • AirMateAir Mate Logo
    • AMPCOAnsul logo
    • TrionTrion IAQ logo
    • TriatekTriatek logo
  • Security
    • American DynamicsTyco American Dynamics logo
    • Bentel SecurityTyco Bentel Security logo
    • CEM SystemsTyco CEM Systems logo
    • DSCTyco DSC logo
    • ExacqTyco Exacq logo
    • IllustraTyco Illustra logo
    • KantechTyco Kantech logo
    • Software HouseTyco Software House logo
  • Digital Solutions
    • Johnson ControlsJCI logo
  • Industrial Refrigeration
    • YorkYORK logo
    • FrickFrick Industrial Refrigeration logo
    • SabroeSabroe logo
  • Fire Suppression
    • tycoTyco Blue Logo
    • AnsulAnsul
    • ChemguardChemguard logo
    • SkumSkum logo
    • HygoodHygood logo
    • GrinnellGrinell logo
    • SprinkCADSprinkCAD logo
    • Pyro ChemPyro-Chem logo
    • AquaMistAnsul logo
  • Retail Solutions
    • Sensormatic
    • ShopperTrakShopperTrak
    • TrueVueTrueVUE logo
  • Residential and Smart Home
    • Johnson ControlsJCI logo
    • LUXLUX logo
  • Building Automation & Controls
    • Johnson ControlsJCI logo
    • MetasysMetasys logo
    • PENNPenn logo
    • Facility ExplorerFacility Explorer logo
    • VerasysVerasys logo
    • BCPROAnsul logo
  • Fire Detection
    • AutocallAnsul logo
    • FireClassFireClass logo
    • SimplexSimplex logo
    • VigilantVigilant logo
    • ZettlerZettler logo
    • DBEDBE written on a white background
  • Distributed Energy Storage
    • Johnson ControlsJCI logo
JohnsonControls logo
  • Products & Solutions
    Products & Solutions
    • Sprinklers, Nozzles & Accessories
    • Valves, Devices, & Components
    • Fire Grooved
    • Corrosion Solutions
    • Antifreeze
    • Flexible Hose Assemblies and Components
    • MLC-S Pipe System
    • Performance Based Design
    • Smart Prefabricated Solutions
  • Services and Support
    Services and Support
    • Design Services
      Design Services
      • Design Services
      • CAD Files
      • Revit Files
      • Fluid Delivery Time (FDT) Calculation Request Form
    • Training
  • Resources
    Resources
    • Resources Library
    • Technical Datasheets
    • Tech Data Update Summaries
    • Global Fire Sprinkler Guide
    • Regional Product Catalogs
    • Americas Price Book
    • Terms and Conditions
  • Insights
Search Contact Us

Search

Clear
SearchLoading
  1. Tyco-Fire
  2. Products and Solutions
  3. Valves, Devices, and Components
  4. Deluge and Preaction Valves and Components
  5. DV-5A Deluge Red-E Cabinet
Product Image_RED-E-D_2
Product Image_RED-E-D_3
Product Image_RED-E-D_4
Product Image_RED-E-D_5
Product Image_RED-E-D_6
Product Image_RED-E-D_7
Product Image_RED-E-D_8
Product Image_RED-E-D_9
Product Image_RED-E-P_3
Product Image_RED-E-D_10
  • Thumb Image_RED-E-D_8.png
  • Thumb Image_RED-E-D_9.png
  • Product Image_RED-E-P_3
  • Thumb Image_RED-E-D_10.png
  • Thumb Image_RED-E-D_2.png
  • Thumb Image_RED-E-D_3.png
  • Thumb Image_RED-E-D_4.png
  • Thumb Image_RED-E-D_5.png
  • Thumb Image_RED-E-D_6.png
  • Thumb Image_RED-E-D_7.png
  • Thumb Image_RED-E-D_8.png
  • Thumb Image_RED-E-D_9.png
  • Product Image_RED-E-P_3
  • Thumb Image_RED-E-D_10.png
  • Thumb Image_RED-E-D_2.png
  • Thumb Image_RED-E-D_3.png
  • Thumb Image_RED-E-D_4.png
  • Thumb Image_RED-E-D_5.png
  • Thumb Image_RED-E-D_6.png
  • Thumb Image_RED-E-D_7.png
  • Thumb Image_RED-E-D_8.png
  • Thumb Image_RED-E-D_9.png
  • Product Image_RED-E-P_3
  • Thumb Image_RED-E-D_10.png

DV-5A Deluge Red-E Cabinet

Pre-assembled, pre-wired, and pre-tested

System and Actuation Type Deluge (Wet, Dry, Electric)
Listings and Approvals UL, C-UL, and CSFM Listed; FM Approved *See technical data sheet for details
Sizes 1½-inch (DN40) to 8-inch (DN200)
Back to Top

DV-5A Deluge Red-E Cabinet

  • Overview
  • Features & Benefits
  • Related Products
  • Specifications
  • Technical Resources
Contact Us

Easy Installation, Efficient Maintenance, and Trusted Performance

The Tyco® Red-E Cabinet is a fire protection valve package enclosed within a free-standing, 14-gauge steel cabinet. The cabinet is designed to occupy minimal floor space and provides an enclosure for the fire protection valve riser. The valve package includes the system (manual) shut-off control valve, automatic water control valve, and water-flow/supervisory switches. The system is also available with an optional built-in air compressor, optional control panel, and backup batteries for providing electrical alarm, supervisory, and trouble function.
Easy Installation, Efficient Maintenance, and Trusted Performance

Features

  • Preassembled, pre-tested and pre-wired to reduce labor
  • Extendable compressor pulls out for access
  • Features the DV-5A valve with a one-piece diaphragm for simple maintenance and quick external reset
  • Available options — air compressor, control panel, seismic kit
  • Remote-resetting and pressure-reducing models available
  • Fully hinged removable double doors provide convenient access to internal parts
  • Equipped with magnetic light strips for clear interior visibility
  • Includes the system (manual) shut-off control valve, automatic water control valve, and water-flow/supervisory switches
  • Deluge system options include wet, dry and electric actuation
  • Also offered for preaction systems

Benefits

Easy Access
Easy Access

Removable and fully hinged double-doors provide convenient access to internal parts and the extendable compressor stored at the bottom of the cabinet.

Efficient Maintenance
Efficient Maintenance

Equipped with magnetic light strips for clear interior visibility. The built-in compressor also pulls out.

Quick Visibility
Quick Visibility

Windows allow for viewing the releasing panel functions & essential system pressure gauges. Motion-activated lights make viewing easy even in darkened rooms.

Mobile Design
Mobile design

Forklift compatibility and industrial grade rollers make the cabinet easy to move into position.

Related Products

DV-5A Pretrim Deluge Valve

DV-5A Pretrim Deluge Valve

FTR-1 Fixed Temperature Release

FTR-1 Fixed Temperature Release

DV-5A Preaction Red-E Cabinet

DV-5A Preaction Red-E Cabinet

Technical Specification

Listings and Approvals UL, C-UL, and CSFM Listed; FM Approved *See technical data sheet for details Minimum Ambient Temperature 40°F (4°C)
Prefab Piping Schedule 40 steel Pressure Rating Valve: 20 to 300 psi (1,4 to 20,7 bar) Trim: See technical data sheet for details
Sizes 1½-inch (DN40) to 8-inch (DN200) System and Actuation Type Deluge (Wet, Dry, Electric)

Technical Resources

Document Name
Description
Language
Resource Type

Data Sheet

TFP1301 Technical Data Sheet  (English)

DV-5A Deluge Red-E Cabinet - TFP1301 (English) Integrated Deluge Fire Protection Package

English Data Sheet
VIEW

Brochure

Red_E-Cabinet_DV-5A_Brochure_7-19 (English)

Red-E Cabinet Featuring the DV-5A Valve

English Brochure
VIEW

Installation Guide

Red-E-DV-5A-Installers-Manual_8-19 (English)

Red-E Cabinet DV-5A

English Installation Guide
VIEW

Video

TYCO® Red-E Cabinet Overview (English)

Red-E Cabinet Overview

English Video
VIEW

Data Sheet

TFP1401 Technical Data Sheet (English)

DV-5A Preaction Red-E Cabinet - TFP1401 (English) Integrated Preaction Fire Protection Package

English Data Sheet
VIEW

Revit File

Red-E Cabinet 4 In (English)

DV-5A Preaction Red-E Cabinet TFP1401 (4" / DN100) - Imperial

English Revit File
VIEW

Revit File

Red-E Cabinet 6 In (English)

DV-5A Preaction Red-E Cabinet TFP1401 (6" / DN150) - Imperial

English Revit File
VIEW

Revit File

Red-E Cabinet 8 In (English)

DV-5A Preaction Red-E Cabinet TFP1401 (8" / DN200) - Imperial

English Revit File
VIEW

Revit File

EMEA Cabinet DN150 (English)

DV-5A Preaction Red-E Cabinet TFP1401 (DN150) - Metric

English Revit File
VIEW

Installation Manual (IM)

Red-E Cabinet Installation Manual (English)

Red-E Cabinet

English Installation Manual (IM)
VIEW

Data Sheet

TFP1303 Technical Data Sheet (English)

DV-5A Red-E Cabinet Integrated Fire Protection Package Single and Double Interlock Preaction, EMEA Only

English Data Sheet
VIEW
No resource found for selected filter

Back

Next

Looking for more Resources
A laptop on a desk with a finger pointing at a screen

SprinkCAD Software Suite 

Save time and ensure quality with the SprinkCAD software suite. Developed to offer fire sprinkler system designers a powerful set of digital tools to create precise solutions. 

Learn about our all-in-one software package
Contact Us
  • Antifreeze
  • Corrosion Solutions
  • CPVC
  • Fire Grooved
  • Flexible Hose Assemblies and Components
  • MLC-S Pipe System
  • Performance Based Design
  • Sprinklers, Nozzles and Accessories
  • Valves, Devices, and Components
  • Technical Datasheets
  • Design Files
  • Tech Data Update Summaries
  • Regional Product Catalogs
  • Americas Price Book
  • Insights
  • WARNING: Cancer & Reproductive Harm
  • Regulatory & Health Warnings
  • SVHC statement - CPVC products containing UV-238
Tyco logo
Connect With Us
  • LinkedIn logo
  • Twitter X logo
  • YouTube Play logo
Johnson Controls logo
© 2025 Johnson Controls. All Rights Reserved.
  • JohnsonControls.com
  • Privacy
  • Legal
  • Terms and Conditions
  • Cookie Preferences