Global Directory

  • HVAC Equipment
    • Johnson ControlsJCI logo
    • YorkYORK logo
    • HitachiHitachi
    • LuxaireLuxaire Heating & Cooling logo
    • Championchampion
    • QuantechQuantech logo
    • ColemanColeman logo
    • RuskinRuskin logo
    • EnvirotecEnviro-Tec logo
    • TempmasterTempMaster logo
    • AirMateAir Mate Logo
    • AMPCOAnsul logo
    • TrionTrion IAQ logo
    • TriatekTriatek logo
  • Security
    • American DynamicsTyco American Dynamics logo
    • Bentel SecurityTyco Bentel Security logo
    • CEM SystemsTyco CEM Systems logo
    • DSCTyco DSC logo
    • ExacqTyco Exacq logo
    • IllustraTyco Illustra logo
    • KantechTyco Kantech logo
    • Software HouseTyco Software House logo
  • Digital Solutions
    • Johnson ControlsJCI logo
  • Industrial Refrigeration
    • YorkYORK logo
    • FrickFrick Industrial Refrigeration logo
    • SabroeSabroe logo
  • Fire Suppression
    • tycoTyco Blue Logo
    • AnsulAnsul
    • ChemguardChemguard logo
    • SkumSkum logo
    • HygoodHygood logo
    • GrinnellGrinell logo
    • SprinkCADSprinkCAD logo
    • Pyro ChemPyro-Chem logo
    • AquaMistAnsul logo
  • Retail Solutions
    • Sensormatic
    • ShopperTrakShopperTrak
    • TrueVueTrueVUE logo
  • Residential and Smart Home
    • Johnson ControlsJCI logo
    • LUXLUX logo
  • Building Automation & Controls
    • Johnson ControlsJCI logo
    • MetasysMetasys logo
    • PENNPenn logo
    • Facility ExplorerFacility Explorer logo
    • VerasysVerasys logo
    • BCPROAnsul logo
  • Fire Detection
    • AutocallAnsul logo
    • FireClassFireClass logo
    • SimplexSimplex logo
    • VigilantVigilant logo
    • ZettlerZettler logo
    • DBEDBE written on a white background
  • Distributed Energy Storage
    • Johnson ControlsJCI logo
JohnsonControls logo
  • Products & Solutions
    Products & Solutions
    • Sprinklers, Nozzles & Accessories
    • Valves, Devices, & Components
    • Fire Grooved
    • Corrosion Solutions
    • Antifreeze
    • Flexible Hose Assemblies and Components
    • MLC-S Pipe System
    • Performance Based Design
    • Smart Prefabricated Solutions
  • Services and Support
    Services and Support
    • Design Services
      Design Services
      • Design Services
      • CAD Files
      • Revit Files
      • Fluid Delivery Time (FDT) Calculation Request Form
    • Training
  • Resources
    Resources
    • Resources Library
    • Technical Datasheets
    • Tech Data Update Summaries
    • Global Fire Sprinkler Guide
    • Regional Product Catalogs
    • Americas Price Book
    • Terms and Conditions
  • Insights
Search Contact Us

Search

Clear
SearchLoading
  1. Tyco-Fire
  2. Products and Solutions
  3. Sprinklers, Nozzles, and Accessories
  4. Storage
  5. Model ESFR-34 Sprinkler
ESFR-34_FIS Product Image1
  • ESFR-34_FIS Thumb Image1

Model ESFR-34 Sprinkler

Early suppression, fast response

Orientation Pendent
K-Factor 33.6
Temperature Rating Up to 212° F
Response Fast
Back to Top

ESFR Rapid Install Sprinklers

  • Overview
  • Features & Benefits
  • Related Products
  • Specifications
  • Technical Resources
Contact Us

The Ideal Choice for Protecting High-Piled Storage

The Model ESFR-34 sprinklers are advantageous when eliminating in-rack sprinklers for the protection of high-piled storage. Their heavy discharge helps attack burning fuel and protects most encapsulated or nonencapsulated common materials, including cartoned and unexpanded plastic. These suppression-mode sprinklers can protect a storage arrangement of 50 feet (15.2 meters) with a ceiling height of 55 feet (16.8 meters) without requiring in-rack sprinklers. In addition, it can be installed with a maximum centerline of a thermal sensing element-to-ceiling distance of 17 inches (432 millimeters).
The Ideal Choice for Protecting High-Piled Storage

Features

  • Offers most flexible storage arrangement options for ceiling-only protection designs
  • For early suppression, fast response (TY9286), see TFP338 for technical information and listing details
  • FM Approved

Benefits

Ceiling-Only Protection
Ceiling-Only Protection

These sprinklers provide suppression mode performance with ceiling-only fire protection.

Flexibility
Flexibility

Our sprinklers protect a wide variety of commodities and storage arrangements.

Trusted Performance
Trusted Performance

Tyco® products have helped to protect spaces for more than 130 years.

Related Products

Model ESFR-22 Sprinkler

Model ESFR-22 Sprinkler

Model ESFR-25 Sprinkler

Model ESFR-25 Sprinkler

Model LD Sprinkler

Model LD Sprinkler

ESFR Rapid Install Sprinklers

ESFR Rapid Install Sprinklers

Technical Specification

Hazard Storage Listings and Approvals FM Approved
Note See Technical Data Sheet for details SIN Numbers TY9286
Thread 1-¼-inch Wrench W-Type 26

Technical Resources

Document Name
Description
Language
Resource Type

Data Sheet

TFP338 Technical Data Sheet (English)

ESFR-34 Sprinklers - TFP338 (English) Pendent, Early Suppression, Fast Response, K-factor = 33.6

English Data Sheet
VIEW

Flyer

FS2004004_ESFR-34NPIProductFlyer_4_Letter_print (English)

Product Overview: ESFR-34

English Flyer
VIEW

Brochure

Tyco-Storage-Fire-Sprinkler-Applications_10-20 (English)

Fire Sprinkler Solutions for Storage Applications

English Brochure
VIEW

Video

10687-1-Storaga-Solutions-Update-100720-v2 (English)

TYCO® Storage Sprinkler Solutions

English Video
VIEW

Case Study

ESFR-34 Storage Spotlight CS_9-20 (English)

Project Spotlight: ESFR-34, South America

English Case Study
VIEW

White Paper

FS2004011_ESFR-34 NPI_WhitePaper_FINAL_SinglePages_Letter (English)

ESFR Storage Sprinklers

English White Paper
VIEW

Data Sheet

TFP338_ES Technical Data Sheet – Spanish Translation (Spanish)

ESFR-34 Sprinklers - TFP338 (Spanish) Pendent, Early Suppression, Fast Response, K-factor = 33.6

Spanish Data Sheet
VIEW

Data Sheet

TFP338_DE Technical Data Sheet – German Translation (German)

ESFR-34 Sprinklers - TFP338 (German) Pendent, Early Suppression, Fast Response, K-factor = 33.6

German Data Sheet
VIEW

Data Sheet

TFP338_SV Technical Data Sheet – Swedish Translation (Swedish-Sweden)

ESFR-34 Sprinklers - TFP338 (Swedish) Pendent, Early Suppression, Fast Response, K-factor = 33.6

Swedish-Sweden Data Sheet
VIEW

Data Sheet

TFP338_FR Technical Data Sheet – French Translation (French)

ESFR-34 Sprinklers - TFP338 (French) Pendent, Early Suppression, Fast Response, K-factor = 33.6

French Data Sheet
VIEW

Data Sheet

TFP338_HU Technical Data Sheet – Hungarian Translation

ESFR-34 Sprinklers - TFP338 (Hungarian) Pendent, Early Suppression, Fast Response, K-factor = 33.6

Data Sheet
VIEW

Data Sheet

TFP338_IT Technical Data Sheet – Italian Translation (Italian-Italy)

ESFR-34 Sprinklers - TFP338 (Italian) Pendent, Early Suppression, Fast Response, K-factor = 33.6

Italian-Italy Data Sheet
VIEW

Data Sheet

TFP338_LS Technical Data Sheet Spanish (Latin America) Translation (Spanish)

ESFR-34 Sprinklers - TFP338 (Latin America) Pendent, Early Suppression, Fast Response, K-factor = 33.6

Spanish Data Sheet
VIEW

Data Sheet

TFP338_PL Technical Data Sheet – Polish Translation

ESFR-34 Sprinklers - TFP338 (Polish) Pendent, Early Suppression, Fast Response, K-factor = 33.6

Data Sheet
VIEW

Data Sheet

TFP338_RU Technical Data Sheet – Russian Translation (Russian-Russia)

ESFR-34 Sprinklers - TFP338 (Russian) Pendent, Early Suppression, Fast Response, K-factor = 33.6

Russian-Russia Data Sheet
VIEW

Data Sheet

TFP338_TR Technical Data Sheet

ESFR-34 Sprinklers - TFP338 (Turkish) Pendent, Early Suppression, Fast Response, K-factor = 33.6

Data Sheet
VIEW

Revit File

TY-9286-Imperial (English)

ESFR-34-TY-9286 (Imperial)

English Revit File
VIEW

Revit File

TY-9286-Metric (English)

ESFR-34-TY-9286 (Metric)

English Revit File
VIEW
No resource found for selected filter

Back

Next

Looking for more Resources
A laptop on a desk with a finger pointing at a screen

SprinkCAD Software Suite 

Save time and ensure quality with the SprinkCAD software suite. Developed to offer fire sprinkler system designers a powerful set of digital tools to create precise solutions. 

Learn about our all-in-one software package
Contact Us
  • Antifreeze
  • Corrosion Solutions
  • CPVC
  • Fire Grooved
  • Flexible Hose Assemblies and Components
  • MLC-S Pipe System
  • Performance Based Design
  • Sprinklers, Nozzles and Accessories
  • Valves, Devices, and Components
  • Technical Datasheets
  • Design Files
  • Tech Data Update Summaries
  • Regional Product Catalogs
  • Americas Price Book
  • Insights
  • WARNING: Cancer & Reproductive Harm
  • Regulatory & Health Warnings
  • SVHC statement - CPVC products containing UV-238
Tyco logo
Connect With Us
  • LinkedIn logo
  • Twitter X logo
  • YouTube Play logo
Johnson Controls logo
© 2025 Johnson Controls. All Rights Reserved.
  • JohnsonControls.com
  • Privacy
  • Legal
  • Terms and Conditions
  • Cookie Preferences