Model RFII–HSW Sprinkler – Sprinklers, Nozzles & Accessories | Tyco Fire

Global Directory

  • HVAC Equipment
    • Johnson ControlsJCI logo
    • YorkYORK logo
    • Championchampion
    • ColemanColeman logo
    • EnvirotecEnviro-Tec logo
    • LuxaireLuxaire Heating & Cooling logo
    • Miller-Picking
    • Pace
    • QuantechQuantech logo
    • Silent-Aire
    • TempmasterTempMaster logo
    • TriatekTriatek logo
  • Industrial Refrigeration
    • YorkYORK logo
    • FrickFrick Industrial Refrigeration logo
    • M&M Carnot
    • SabroeSabroe logo
    • York Process Systemsyork-process-system-logo
  • Digital Solutions
    • OpenBlueOpenBlue Logo
    • FM:Systems
  • Building Automation and Controls
    • Johnson ControlsJCI logo
    • MetasysMetasys logo
    • Facility ExplorerFacility Explorer logo
    • EasyIOEasyio Logo
    • VerasysVerasys logo
    • BCProAnsul logo
    • PENNPenn logo
  • Retail Solutions
    • Sensormatic
  • Fire Suppression
    • Tyco Firetyco
    • ANSULAnsul
    • ChemguardChemguard logo
    • SkumSkum logo
    • HygoodHygood logo
    • GrinnellGrinell logo
    • SprinkCADSprinkCAD logo
    • Pyro ChemPyro-Chem logo
    • AquaMistAnsul logo
  • Fire Detection
    • AutocallAnsul logo
    • FireClassFireClass logo
    • SimplexSimplex logo
    • ZettlerZettler logo
    • VigilantVigilant logo
    • DBEDBE written on a white background
  • Security
    • American DynamicsAmerican Dynamics Logo
    • DSCDSC written on a white background
    • ExacqExacq-gray
    • IllustraIllustra logo
    • KantechKantech logo on a white background
    • QolsysQolysys logo
    • Software HouseSoftware House logo
    • Bentel Security Bentel Logo
    • CEM SystemsCEM Systems written on a white background
    • CloudvueCloudvue logo
    • SES
    • VisonicVisonic logo
JCI Logo
  • Products & Solutions
    Products & Solutions
    • Sprinklers, Nozzles & Accessories
      Sprinklers, Nozzles & Accessories
      • Sprinklers Nozzles Accessories
      • Standard Coverage
      • Nozzles
      • Dry
      • Extended Coverage
      • Sprinkler Accessories
      • Special Application
      • Storage
      • Residential
    • Valves, Devices, & Components
      Valves, Devices, & Components
      • Valves Devices and Components
      • Air Maintenance Devices
      • System Components
      • Dry System Valves
      • Accelerators
      • Deluge and Preaction Valves and Components
      • General Purpose Valves
      • Wet System Valves and Components
      • Fire Sprinkler Switches
    • Fire Grooved
    • Corrosion Solutions
    • Antifreeze
    • Flexible Hose Assemblies and Components
    • MLC-S Pipe System
      MLC-S Pipe System
      • MLC-S Pipe System
      • Fittings
      • Tools
      • Pipes
      • Casting Cup
    • Performance Based Design
      Performance Based Design
      • Performance Based Design
      • EAS-1
      • Quell or Vanquish
    • Smart Prefabricated Solutions
  • Services and Support
    Services and Support
    • Design Services
      Design Services
      • Design Services
      • CAD Files
      • Revit Files
      • Fluid Delivery Time (FDT) Calculation Request Form
    • Training
  • Resources
    Resources
    • Resources Library
    • Technical Datasheets
    • Tech Data Update Summaries
    • Global Fire Sprinkler Guide
    • Regional Product Catalogs
    • Americas Price Book
    • Terms and Conditions
  • Insights
Search Contact Us

Search

Clear
SearchLoading
  1. Tyco-Fire
  2. Products and Solutions
  3. Sprinklers, Nozzles, and Accessories
  4. Extended Coverage
  5. Model RFIII-HSW Sprinkler
RFIII-HSW_FIS Product Image1
RFIII-HSW_FIS Product Image2
  • RFIII-HSW_FIS Thumb Image1
  • RFIII-HSW_FIS Thumb Image2

Model RFIII-HSW Sprinkler

8.0 K-factor concealed horizontal sidewall sprinkler

Orientation Concealed Horizontal Sidewall
K-Factor 8
Temperature Rating 160°F
Response Quick
Back to Top

Model RFIII-HSW Sprinkler

  • Overview
  • Features & Benefits
  • Related Products
  • Specifications
  • Technical Resources
Contact Us

Quick Response, Extended Coverage

The Tyco® Model RFIII 8.0 K-factor, extended coverage light hazard, concealed horizontal sidewall quick-response sprinkler is a decorative link-type sprinkler featuring a unique flat cover designed to conceal the sprinkler within a wall. This sprinkler is an ideal choice for architecturally sensitive, light-hazard areas such as dormitories, hotel rooms, reception areas, office buildings, banquet facilities, conference rooms, and hospitals. The flat profile of the cover plate design easily conforms to the surrounding surfaces, leaving a very clean look. While the plate is aesthetically appealing, it also helps prevent objects such as garment bags and clothes hangers from being hung from the sprinkler, potentially causing an inadvertent operation.
Quick Response, Extended Coverage

Features

  • Long throw up to 24 ft. of extended coverage
  • UL and C-UL Listed
  • Coverage areas up to 16 ft. x 24 ft. (4,9 x 7,3 m) and 18 ft. x 22 ft. (5,9 m x 6,7 m)
  • For 8.0 K-factor concealed horizontal sidewall sprinkler (TY4522), see TFP270 for technical information and listing details

Benefits

Discreet Design
Discreet Design

A flat cover plate assembly conceals the sprinkler to offer a seamless look.

Efficient
Efficient

Coverage areas meet your needs.

Trusted Performance
Trusted Performance

Tyco® products have helped to protect spaces for more than 130 years.

Related Products

Series RFII Extended Coverage Sprinkler

Series RFII Extended Coverage Sprinkler

Series RFII-C Sprinkler

Series RFII-C Sprinkler

Sprinkler Cover Plate Assemblies, Escutcheons, Guards and Shields

Sprinkler Cover Plate Assemblies, Escutcheons, Guards and Shields

Technical Specification

Hazard Light Listings and Approvals UL and C-UL Listed
SIN Numbers TY4522 Thread ¾ inch
Wrench W37    

Technical Resources

Document Name
Description
Language
Resource Type

Data Sheet

TFP270 – Technical Data Sheet  (English)

RFIII-HSW Sprinkler - TFP270 (English) Flat Plate Concealed, Horizontal, Extended Coverage, Quick Response Light Hazard Sidewall, K-factor = 8.0

English Data Sheet
VIEW

Flyer

31543_JC_RFIII_EC_Sidewall_Sprinkler_12-17_MMr1 (English)

Product Overview: Tyco® BlazeMaster CPVC Pipe & Fittings

English Flyer
VIEW

Brochure

Tyco-Aesthetic-Brochure-Fire-Sprinklers-5-20 (English)

Aesthetic Fire Sprinkler Options

English Brochure
VIEW

Flyer

Custom-Paint-Cover-Plates_7-18 (English)

Product Overview: Custom Paint Cover Plate Options

English Flyer
VIEW

Flyer

31543_JC_Cover_Plate_Tool_Cap_10-14_MMr1 (English)

Product Overview: Cover Plate Utility Tool

English Flyer
VIEW

Data Sheet

TFP270_ES Technical Data Sheet – Spanish Translation (Spanish)

RFIII-HSW Sprinkler - TFP270 (Spanish) Flat Plate Concealed Horizontal Extended Coverage, Quick Response Light Hazard Sidewall, K-factor = 8.0

Spanish Data Sheet
VIEW

Data Sheet

TFP270_SV Technical Data Sheet – Swedish Translation (Swedish-Sweden)

RFIII-HSW Sprinkler - TFP270 (Swedish) Flat Plate Concealed Horizontal Extended Coverage, Quick Response Light Hazard Sidewall, K-factor = 8.0

Swedish-Sweden Data Sheet
VIEW

Data Sheet

TFP270_FR Technical Data Sheet – French Translation (French)

RFIII-HSW Sprinkler - TFP270 (French) Flat Plate Concealed Horizontal Extended Coverage, Quick Response Light Hazard Sidewall, K-factor = 8.0

French Data Sheet
VIEW

Data Sheet

TFP270_BP Technical Data Sheet Portuguese (Brazil) Translation (Portuguese)

RFIII-HSW Sprinkler - TFP270 (Portuguese - Brazil) Flat Plate Concealed Horizontal Extended Coverage, Quick Response Light Hazard Sidewall, K-factor = 8.0

Portuguese Data Sheet
VIEW

Data Sheet

TFP270_IT Technical Data Sheet – Italian Translation (Italian-Italy)

RFIII-HSW Sprinkler - TFP270 (Italian) Flat Plate Concealed Horizontal Extended Coverage, Quick Response Light Hazard Sidewall, K-factor = 8.0

Italian-Italy Data Sheet
VIEW

Data Sheet

TFP270_LS Technical Data Sheet Spanish (Latin America) Translation (Spanish)

RFIII-HSW Sprinkler - TFP270 (Spanish - Latin American) Flat Plate Concealed Horizontal Extended Coverage, Quick Response Light Hazard Sidewall, K-factor = 8.0

Spanish Data Sheet
VIEW

Data Sheet

TFP270_RU Technical Data Sheet – Russian Translation (Russian-Russia)

RFIII-HSW Sprinkler - TFP270 (Russian) Flat Plate Concealed Horizontal Extended Coverage, Quick Response Light Hazard Sidewall, K-factor = 8.0

Russian-Russia Data Sheet
VIEW
No resource found for selected filter

Back

Next

Looking for more Resources
A laptop on a desk with a finger pointing at a screen

SprinkCAD Software Suite 

Save time and ensure quality with the SprinkCAD software suite. Developed to offer fire sprinkler system designers a powerful set of digital tools to create precise solutions. 

Learn about our all-in-one software package
Contact Us
  • Antifreeze
  • Corrosion Solutions
  • CPVC
  • Fire Grooved
  • Flexible Hose Assemblies and Components
  • MLC-S Pipe System
  • Performance Based Design
  • Sprinklers, Nozzles and Accessories
  • Valves, Devices, and Components
  • Technical Datasheets
  • Design Files
  • Tech Data Update Summaries
  • Regional Product Catalogs
  • Americas Price Book
  • Insights
  • WARNING: Cancer & Reproductive Harm
  • Regulatory & Health Warnings
  • SVHC statement - CPVC products containing UV-238
Tyco logo
Connect With Us
  • LinkedIn logo
  • Twitter X logo
  • YouTube Play logo
JCI Logo
© 2025 Johnson Controls. All Rights Reserved.
  • JohnsonControls.com
  • Privacy
  • Legal
  • Terms and Conditions
  • Cookie Preferences