Series DS–2 Dry Sprinklers–Sprinklers, Nozzles & Accessories | Tyco Fire

Global Directory

  • HVAC Equipment
    • Johnson ControlsJCI logo
    • YORKYORK logo
    • Championchampion
    • ColemanColeman logo
    • EnvirotecEnviro-Tec logo
    • LuxaireLuxaire Heating & Cooling logo
    • Miller-Picking
    • Pace
    • QuantechQuantech logo
    • Silent-Aire Silent- Aire logo
    • TempmasterTempMaster logo
    • TriatekTriatek logo
  • Industrial Refrigeration
    • YORKYORK logo
    • FrickFrick Industrial Refrigeration logo
    • M&M Carnot
    • SabroeSabroe logo
    • York Process Systemsyork-process-system-logo
  • Digital Solutions
    • OpenBlueOpenBlue Logo
    • FM:Systems
  • Building Automation and Controls
    • Johnson ControlsJCI logo
    • MetasysMetasys icon
    • Facility Explorerfacility explorer
    • EasyIOeasyio text
    • VerasysVerasys logo
    • BCProAnsul logo
    • PENNpenn
  • Retail Solutions
    • Sensormatic
  • Fire Suppression
    • Tyco Firetyco
    • ANSULAnsul
    • ChemguardChemguard logo
    • SkumSkum logo
    • HygoodHygood logo
    • GrinnellGrinell logo
    • SprinkCADSprinkCAD logo
    • Pyro ChemPyro-Chem logo
    • AquaMistAnsul logo
  • Fire Detection
    • AutocallAnsul logo
    • FireClassFireClass logo
    • SimplexSimplex logo
    • ZettlerZettler logo
    • VigilantVigilant logo
    • DBEDBE written on a white background
  • Security
    • American DynamicsAmerican Dynamics Logo
    • DSCDSC written on a white background
    • ExacqExacq-gray
    • IllustraIllustra logo
    • KantechKantech logo on a white background
    • QolsysQolysys logo
    • Software HouseSoftware House logo
    • Bentel Security Bentel Logo
    • CEM SystemsCEM Systems written on a white background
    • CloudvueCloudvue logo
    • SESSES Logo Image
    • VisonicVisonic logo
JCI Logo
  • Products & Solutions
    Products & Solutions
    • Sprinklers, Nozzles & Accessories
      Sprinklers, Nozzles & Accessories
      • Sprinklers Nozzles Accessories
      • Standard Coverage
      • Nozzles
      • Dry
      • Extended Coverage
      • Sprinkler Accessories
      • Special Application
      • Storage
      • Residential
    • Valves, Devices, & Components
      Valves, Devices, & Components
      • Valves Devices and Components
      • Air Maintenance Devices
      • System Components
      • Dry System Valves
      • Accelerators
      • Deluge and Preaction Valves and Components
      • General Purpose Valves
      • Wet System Valves and Components
      • Fire Sprinkler Switches
    • Fire Grooved
    • Corrosion Solutions
    • Antifreeze
    • Flexible Hose Assemblies and Components
    • MLC-S Pipe System
      MLC-S Pipe System
      • MLC-S Pipe System
      • Fittings
      • Tools
      • Pipes
      • Casting Cup
    • Performance Based Design
      Performance Based Design
      • Performance Based Design
      • EAS-1
      • Quell or Vanquish
    • Smart Prefabricated Solutions
  • Services and Support
    Services and Support
    • Design Services
      Design Services
      • Design Services
      • CAD Files
      • Revit Files
      • Fluid Delivery Time (FDT) Calculation Request Form
    • Training
  • Resources
    Resources
    • Resources Library
    • Technical Datasheets
    • Tech Data Update Summaries
    • Global Fire Sprinkler Guide
    • Regional Product Catalogs
    • Americas Price Book
    • Terms and Conditions
  • Insights
Search Contact Us

Search

Clear
SearchLoading
  1. Tyco-Fire
  2. Products and Solutions
  3. Sprinklers, Nozzles, and Accessories
  4. Dry
  5. Series DS-2 Dry Sprinklers
DS-2_FIS Product Image1
DS-2_FIS Product Image2
  • DS-2_FIS Thumb Image1
  • DS-2_FIS Thumb Image2

Series DS-2 Dry Sprinklers

Pendent extended coverage, standard and quick response

Orientation Pendent
K-Factor 11.2
Temperature Rating Up to 286°F
Response Quick, Standard
Back to Top

Series DS-2 Dry Sprinklers

  • Overview
  • Features & Benefits
  • Related Products
  • Specifications
  • Technical Resources
Contact Us

Wet or Dry Sprinklers Ideal for Use in Freezing Temperatures

Due to the potential for ambient freezing temperatures to freeze the water within the system piping, the sprinkler is comprised of a long dry barrel that separates the sealed water inlet from the activation element and frame/deflector assembly. Water is prevented from entering the dry sprinkler assembly until the temperature within the protected space is high enough to break the activation element thereby releasing the seal. Once the seal is released, the sprinkler is activated and water automatically releases.
Wet or Dry Sprinklers Ideal for Use in Freezing Temperatures

Features

  • Extra-large orifice
  • UL and C-UL Listed; NYC Approved
  • For standard and quick response, standard coverage (TY5255, TY5235), see TFP530 for technical information and listing details
  • Length up to 48 inches (1220 mm)
  • For Pendent extended coverage (TY5238), see TFP540 for technical information and listing details

Benefits

Customizable
Customizable

Dry sprinklers are made-to-order to ensure a perfect fit for your project.

Timely
Timely

We set the industry standard for delivery times of custom dry sprinkler orders.

Trusted Performance
Trusted Performance

Tyco® products have helped to protect spaces for more than 130 years.

Related Products

Series DS-1 Dry Sprinklers

Series DS-1 Dry Sprinklers

Series DS-3 Dry Sprinklers

Series DS-3 Dry Sprinklers

Series DS-8 Dry Sprinklers

Series DS-8 Dry Sprinklers

Series DS-ECC Dry Sprinklers

Series DS-ECC Dry Sprinklers

Technical Specification

Hazard Light, Ordinary Coverage Standard, Extended​
Listings and Approvals UL and C-UL Listed; NYC Approved Note See Technical Data Sheet for details
SIN Numbers TY5238, TY5255, TY5235 Thread 1-inch
Wrench Recessed W17 Wrench Pipe

Technical Resources

Document Name
Description
Language
Resource Type

Data Sheet

TFP530 – Technical Data Sheet  (English)

DS-2 Dry Sprinklers - TFP530 (English) Pendent, Standard and Quick Response, Standard Coverage, K-factor = 11.2

English Data Sheet
VIEW

Data Sheet

TFP540 – Techincal Data Sheet  (English)

DS-2 Dry Sprinklers - TFP540 (English) Pendent, Extended Coverage, Light and Ordinary Hazard, K-factor = 11.2 

English Data Sheet
VIEW

Frequently Asked Questions

FS2010004_DS-8_Sprinkers_NPI_Campaign_FAQ_Final (English)

DS-8 Sprinklers

English Frequently Asked Questions
VIEW

Data Sheet

TFP540_SV Technical Data Sheet – Swedish Translation (Swedish-Sweden)

DS-2 Dry Sprinklers - TFP540 (Swedish) Pendent, Extended Coverage, Light and Ordinary Hazard, K-factor = 11.2

Swedish-Sweden Data Sheet
VIEW
No resource found for selected filter

Back

Next

Looking for more Resources
A laptop on a desk with a finger pointing at a screen

SprinkCAD Software Suite 

Save time and ensure quality with the SprinkCAD software suite. Developed to offer fire sprinkler system designers a powerful set of digital tools to create precise solutions. 

Learn about our all-in-one software package
Contact Us
  • Antifreeze
  • Corrosion Solutions
  • CPVC
  • Fire Grooved
  • Flexible Hose Assemblies and Components
  • MLC-S Pipe System
  • Performance Based Design
  • Sprinklers, Nozzles and Accessories
  • Valves, Devices, and Components
  • Technical Datasheets
  • Design Files
  • Tech Data Update Summaries
  • Regional Product Catalogs
  • Americas Price Book
  • Insights
  • WARNING: Cancer & Reproductive Harm
  • Regulatory & Health Warnings
  • SVHC statement - CPVC products containing UV-238
Tyco logo
Connect With Us
  • LinkedIn logo
  • Twitter X logo
  • YouTube Play logo
JCI Logo
© 2025 Johnson Controls. All Rights Reserved.
  • JohnsonControls.com
  • Privacy
  • Legal
  • Terms and Conditions
  • Cookie Preferences