TSV-D SMART Dry System Air Vent – Corrosion Solutions | Tyco Fire

Global Directory

  • HVAC Equipment
    • Johnson ControlsJCI logo
    • YorkYORK logo
    • HitachiHitachi
    • LuxaireLuxaire Heating & Cooling logo
    • Championchampion
    • QuantechQuantech logo
    • ColemanColeman logo
    • RuskinRuskin logo
    • EnvirotecEnviro-Tec logo
    • TempmasterTempMaster logo
    • AirMateAir Mate Logo
    • AMPCOAnsul logo
    • TrionTrion IAQ logo
    • TriatekTriatek logo
  • Security
    • American DynamicsTyco American Dynamics logo
    • Bentel SecurityTyco Bentel Security logo
    • CEM SystemsTyco CEM Systems logo
    • DSCTyco DSC logo
    • ExacqTyco Exacq logo
    • IllustraTyco Illustra logo
    • KantechTyco Kantech logo
    • Software HouseTyco Software House logo
  • Digital Solutions
    • Johnson ControlsJCI logo
  • Industrial Refrigeration
    • YorkYORK logo
    • FrickFrick Industrial Refrigeration logo
    • SabroeSabroe logo
  • Fire Suppression
    • tycoTyco Blue Logo
    • AnsulAnsul
    • ChemguardChemguard logo
    • SkumSkum logo
    • HygoodHygood logo
    • GrinnellGrinell logo
    • SprinkCADSprinkCAD logo
    • Pyro ChemPyro-Chem logo
    • AquaMistAnsul logo
  • Retail Solutions
    • Sensormatic
    • ShopperTrakShopperTrak
    • TrueVueTrueVUE logo
  • Residential and Smart Home
    • Johnson ControlsJCI logo
    • LUXLUX logo
  • Building Automation & Controls
    • Johnson ControlsJCI logo
    • MetasysMetasys logo
    • PENNPenn logo
    • Facility ExplorerFacility Explorer logo
    • VerasysVerasys logo
    • BCPROAnsul logo
  • Fire Detection
    • AutocallAnsul logo
    • FireClassFireClass logo
    • SimplexSimplex logo
    • VigilantVigilant logo
    • ZettlerZettler logo
    • DBEDBE written on a white background
  • Distributed Energy Storage
    • Johnson ControlsJCI logo
JohnsonControls logo
  • Products & Solutions
    Products & Solutions
    • Sprinklers, Nozzles & Accessories
    • Valves, Devices, & Components
    • Fire Grooved
    • Corrosion Solutions
    • Antifreeze
    • Flexible Hose Assemblies and Components
    • MLC-S Pipe System
    • Performance Based Design
    • Smart Prefabricated Solutions
  • Services and Support
    Services and Support
    • Design Services
      Design Services
      • Design Services
      • CAD Files
      • Revit Files
      • Fluid Delivery Time (FDT) Calculation Request Form
    • Training
  • Resources
    Resources
    • Resources Library
    • Technical Datasheets
    • Tech Data Update Summaries
    • Global Fire Sprinkler Guide
    • Regional Product Catalogs
    • Americas Price Book
    • Terms and Conditions
  • Insights
Search Contact Us

Search

Clear
SearchLoading
  1. Tyco-Fire
  2. Products and Solutions
  3. Corrosion Solutions
  4. TSV-D SMART Dry System Air Vent
Product Image_TSV-D_1
Product Image_TSV-D_2
Product Image_TSV-D_3
Product Image_TSV-D_4
  • Thumb Image_TSV-D_1.png
  • Thumb Image_TSV-D_2.png
  • Thumb Image_TSV-D_3.png
  • Thumb Image_TSV-D_4.png

TSV-D SMART Dry System Air Vent

Provides automatic oxygen venting

System Type Dry, Preaction
Product Type Oxygen Removal Vent
Back to Top

TGSK Gas Sampling Kit

  • Overview
  • Features & Benefits
  • Related Products
  • Specifications
  • Technical Resources
Contact Us

Reduce Corrosion with a SMART Air Vent

As a fire sprinkler system is filled with a continuous supply of nitrogen gas from a Tyco® NG-1 Nitrogen Generator, the TSV-D SMART Air Vent allows oxygen-rich gas to be vented from the fire sprinkler system. Over a period of 14 days, the SMART Air Vent almost completely removes oxygen from the fire sprinkler system (< 2% oxygen). After 14 days, the SMART Air Vent automatically closes and prevents continuous venting. The TSV-D SMART Air Vent includes two separate components: the vent assembly and electric control box. A back pressure regulator is also included to prevent total system depressurization from the vent assembly before the vent is electronically closed. The restricted venting orifice allows oxygen to be vented from the fire sprinkler system at a controlled rate to achieve a minimum nitrogen concentration of 98%.
Reduce Corrosion with a SMART Air Vent

Features

  • Two components — vent assembly and electronic control box
  • Includes back pressure regulator to prevent total system depressurization from the vent assembly before the vent is electronically closed
  • Automatic float shut-off in the event of a system trip
  • Equipped with an electronic solenoid valve that must be wired to the electric control box (conductors not included)
  • Levered float valve allows gas to discharge but prevents liquid water from leaking through the restricted venting orifice if water enters the fire sprinkler system
  • Support hanger not required

Benefits

No Remote Equipment
No Remote Equipment

Install the vent directly at the system riser.

Reduce Corrosion
Reduce Corrosion

Nitrogen replaces corrosion-causing oxygen.

Extend Useful Life
Extend Useful Life

Reducing corrosion can extend the service life of a fire sprinkler system.

Minimize Business Interruption
Minimize Business Interruption

System leaks due to corrosion can lead to costly downtime – reducing corrosion helps keep systems healthy and operational.

Related Products

THGA Handheld Gas Analyzer

THGA Handheld Gas Analyzer

TVC-2 & TVC-6 Advanced Vent Controller

TVC-2 & TVC-6 Advanced Vent Controller

Technical Specification

Electrical Connection <2 amps Service Pressure Up to 175 psig (12 bar)
System Connection 1-inch NPT Male Temperature Range 40°F to 120°F (4.5°C to 49°C)

Technical Resources

Document Name
Description
Language
Resource Type

Data Sheet

TFP1263 Technical Data Sheet  (English)

TSV-D SMART Dry System Air Vent - TFP1263 (English) 

English Data Sheet
VIEW

Brochure

Corrosion-Solutions-Fire-Sprinkler-System_7-20 (English)

Corrosion Solutions for Fire Sprinkler Systems

English Brochure
VIEW

Brochure

Tyco-Storage-Fire-Sprinkler-Applications_10-20 (English)

Fire Sprinkler Solutions for Storage Applications

English Brochure
VIEW

Video

NG-1 Nitrogen Generator (English)

NG-1 Nitrogen Generator Overview

English Video
VIEW

Video

Dry Pipe Nitrogen Inerting (DNPI) Process (English)

Dry Pipe Nitrogen Inerting (DNPI) Process

English Video
VIEW

Video

Product Demo of the NG-1 Nitrogen Generator (English)

NG-1 Nitrogen Generator Demonstration

English Video
VIEW

Data Sheet

TFP1263_ES Technical Data Sheet – Spanish Translation (Spanish)

TSV-D SMART Dry System Air Vent - TFP1263 (Spanish)

Spanish Data Sheet
VIEW

Data Sheet

TFP1263_DE Technical Data Sheet – German Translation (German)

TSV-D SMART Dry System Air Vent - TFP1263 (German) 

German Data Sheet
VIEW

Data Sheet

TFP1263_SV Technical Data Sheet – Swedish Translation  (Swedish-Sweden)

TSV-D SMART Dry System Air Vent - TFP1263 (Swedish) 

Swedish-Sweden Data Sheet
VIEW

Data Sheet

TFP1263_DA Technical Data Sheet – Danish Translation 

TSV-D SMART Dry System Air Vent - TFP1263 (Danish) 

Data Sheet
VIEW

Data Sheet

TFP1263_FI Technical Data Sheet – Finnish Translation  

TSV-D SMART Dry System Air Vent - TFP1263 (Finnish) 

Data Sheet
VIEW

Data Sheet

TFP1263_IT Technical Data Sheet – Italian Translation (Italian-Italy)

TSV-D SMART Dry System Air Vent - TFP1263 (Italian)

Italian-Italy Data Sheet
VIEW

Revit File

Model TSV-D Rev (English)

TSV-D Rev-1 - TFP1263

English Revit File
VIEW

Revit File

Model TSV-D (English)

TSV-D - TFP1263

English Revit File
VIEW
No resource found for selected filter

Back

Next

Looking for more Resources
A laptop on a desk with a finger pointing at a screen

SprinkCAD Software Suite 

Save time and ensure quality with the SprinkCAD software suite. Developed to offer fire sprinkler system designers a powerful set of digital tools to create precise solutions. 

Learn about our all-in-one software package
Contact Us
  • Antifreeze
  • Corrosion Solutions
  • CPVC
  • Fire Grooved
  • Flexible Hose Assemblies and Components
  • MLC-S Pipe System
  • Performance Based Design
  • Sprinklers, Nozzles and Accessories
  • Valves, Devices, and Components
  • Technical Datasheets
  • Design Files
  • Tech Data Update Summaries
  • Regional Product Catalogs
  • Americas Price Book
  • Insights
  • WARNING: Cancer & Reproductive Harm
  • Regulatory & Health Warnings
  • SVHC statement - CPVC products containing UV-238
Tyco logo
Connect With Us
  • LinkedIn logo
  • Twitter X logo
  • YouTube Play logo
Johnson Controls logo
© 2025 Johnson Controls. All Rights Reserved.
  • JohnsonControls.com
  • Privacy
  • Legal
  • Terms and Conditions
  • Cookie Preferences