Global Directory

  • HVAC Equipment
    • Johnson ControlsJCI logo
    • YORKyork-process-system-logo
    • Championchampion
    • ColemanColeman logo
    • EnvirotecEnviro-Tec logo
    • LuxaireLuxaire Heating & Cooling logo
    • Miller-Picking
    • Pace
    • QuantechQuantech logo
    • Silent-AireSilentAire Logo
    • TempmasterTempMaster logo
    • TriatekTriatek logo
  • Industrial Refrigeration
    • YORKyork-process-system-logo
    • FrickFrick Industrial Refrigeration logo
    • M&M Carnot
    • SabroeSabroe logo
    • York Process Systemsyork-process-system-logo
  • Digital Solutions
    • OpenBlueOpenBlue Logo
    • FM:Systems
  • Building Automation and Controls
    • Johnson ControlsJCI logo
    • MetasysMetasys icon
    • Facility Explorerfacility explorer
    • EasyIOeasyio text
    • VerasysVerasys logo
    • BCProAnsul logo
    • PENNpenn
  • Retail Solutions
    • Sensormatic
  • Fire Suppression
    • Tyco Firetyco
    • AnsulAnsul
    • ChemguardChemguard logo
    • SkumSkum logo
    • HygoodHygood logo
    • GrinnellGrinell logo
    • SprinkCADSprinkCAD logo
    • Pyro ChemPyro-Chem logo
    • AquaMistaquamist_logo
  • Fire Detection
    • AutocallAnsul logo
    • FireClassFireClass logo
    • SimplexSimplex logo
    • ZettlerZettler logo
    • VigilantVigilant logo
    • DBEDBE written on a white background
  • Security
    • American DynamicsAmerican Dynamics Logo
    • DSCDSC logo
    • ExacqExacq logo
    • IllustraIllustra Blue logo
    • KantechKantech logo
    • IQIQ logo
    • Software HouseSoftware House logo
    • Bentel Security Bentel logo
    • CEM SystemsCEM Systems  logo
    • CloudvueCloudvue logo
    • SESSES Logo Image
    • VisonicVisonic logo
JCI Logo
  • Products & Solutions
    Products & Solutions
    • Sprinklers, Nozzles & Accessories
      Sprinklers, Nozzles & Accessories
      • Sprinklers Nozzles Accessories
      • Standard Coverage
      • Nozzles
      • Dry
      • Extended Coverage
      • Sprinkler Accessories
      • Special Application
      • Storage
      • Residential
    • Valves, Devices, & Components
      Valves, Devices, & Components
      • Valves Devices and Components
      • Air Maintenance Devices
      • System Components
      • Dry System Valves
      • Accelerators
      • Deluge and Preaction Valves and Components
      • General Purpose Valves
      • Wet System Valves and Components
      • Fire Sprinkler Switches
    • Fire Grooved
    • Corrosion Solutions
    • Antifreeze
    • Flexible Hose Assemblies and Components
    • MLC-S Pipe System
      MLC-S Pipe System
      • MLC-S Pipe System
      • Fittings
      • Tools
      • Pipes
      • Casting Cup
    • Performance Based Design
      Performance Based Design
      • Performance Based Design
      • EAS-1
      • Quell or Vanquish
    • Smart Prefabricated Solutions
  • Services and Support
    Services and Support
    • Design Services
      Design Services
      • Design Services
      • CAD Files
      • Revit Files
      • Fluid Delivery Time (FDT) Calculation Request Form
    • Training
  • Resources
    Resources
    • Resources Library
    • Technical Datasheets
    • Tech Data Update Summaries
    • Global Fire Sprinkler Guide
    • Regional Product Catalogs
    • Americas Price Book
    • Terms and Conditions
  • Insights
Search
Contact Us
  1. Tyco-Fire
  2. Products and Solutions
  3. Valves, Devices, and Components
  4. Wet System Valves and Components
  5. RSV-1 Residential Shut-Off Valve
Product Image_RSV-1_1
  • Thumb Image_RSV-1_1.png

RSV-1 Residential Shut-Off Valve

Automatically diverts available water supply to the fire sprinkler system

Listings and Approvals UL and C-UL Listed, NSF Approved
Pressure Rating 175 psi (12,1 bar)
Sizes 1 inch (DN25), 2 inch (DN50)
Back to Top

RSV-1 Residential Shut-Off Valve

  • Overview
  • Features & Benefits
  • Related Products
  • Specifications
  • Technical Resources
    Contact Us

    Self-Resetting Sprinkler Valve

    Tyco® Model RSV-1 residential shut-off valves are designed to be used in dual-purpose residential water supply piping that serves both domestic and residential fire protection sprinkler system needs. When your fire sprinkler operates, the Model RSV-1 residential shut-off valve automatically diverts the available water supply to the fire sprinkler system. This valve maximizes the effective use of an existing water supply — and in areas with limited water supplies, it may eliminate the need to add costly pumps, pressurized reservoirs, or electrically operated domestic shut-off valves. Also, the Model RSV-1 valve automatically resets, so you don’t need to disassemble the valve after a fire sprinkler system test or operation.
    Self-Resetting Sprinkler Valve

    Features

    • Two available sizes: 1-inch (DN25) size is designed for NFPA 13D system needs; the 2-inch (DN50) is designed for either NFPA 13D or NFPA 13R
    • Eliminate the need for electrically operated solenoid valves
    • Flexibility with existing water supplies in retrofit applications and developed lots
    • Able to mitigate local requirements based on mandated domestic load and hydraulic safety factors
    • Can be used in conjunction with backflow preventers
    • Built-in check valve eliminates the need for a separate check valve on the fire sprinkler system
    • Potential cost offsets with reduced pipe size
    • UL and C-UL Listed,; NSF-61 Annex G Approved

    Benefits

    Reduce Costs
    Reduce Costs

    The RSV-1 can eliminate the need for a separate fire line and meter, reducing up front investment and additional maintenance/metering costs long-term.

    Simplify Install
    Simplify Install

    With a built-in check valve, the RSV-1 may remove the need for a separate check valve with the approval of the local water purveyor.

    Trusted Performance
    Trusted Performance

    Tyco® products have helped to protect spaces for more than 130 years.

    Technical Specification

    Connection Type NPT thread Sizes 1 inch (DN25), 2 inch (DN50)
    Listings and Approvals UL and C-UL Listed, NSF Approved Pressure Rating 175 psi (12,1 bar)
    Weight 1 inch (DN25): 11 lbs. (5 kg); 2 inch (DN50): 29 lbs. (11 kg)    

    Technical Resources

    Document Name
    Description
    Language
    Resource Type

    Data Sheet

    TFP982 Technical Data Sheet  (English)

    RSV-1 Residential Shut-Off Valve – TFP982 (English) For Dual-Purpose Water Supply, Domestic and Fire Sprinkler System

    English Data Sheet
    View

    Flyer

    FS2305013_RSV-1 Product Flyer Update-US-letter-DIGITAL (English)

    Model RSV-1 Residential Shut-off Valve

    English Flyer
    View
    No resource found for selected filter

    Back

    Next

    Looking for more Resources
    A laptop on a desk with a finger pointing at a screen

    SprinkCAD Software Suite 

    Save time and ensure quality with the SprinkCAD software suite. Developed to offer fire sprinkler system designers a powerful set of digital tools to create precise solutions. 

    Learn about our all-in-one software package
    Contact Us
    • Antifreeze
    • Corrosion Solutions
    • CPVC
    • Fire Grooved
    • Flexible Hose Assemblies and Components
    • MLC-S Pipe System
    • Performance Based Design
    • Sprinklers, Nozzles and Accessories
    • Valves, Devices, and Components
    • Technical Datasheets
    • Design Files
    • Tech Data Update Summaries
    • Regional Product Catalogs
    • Americas Price Book
    • Insights
    • WARNING: Cancer & Reproductive Harm
    • Regulatory & Health Warnings
    • SVHC statement - CPVC products containing UV-238
    Tyco logo
    Connect With Us
    • LinkedIn logo
    • Twitter X logo
    • YouTube Play logo
    JCI Logo
    © 2025 Johnson Controls. All Rights Reserved.
    • JohnsonControls.com
    • Privacy
    • Legal
    • Terms and Conditions