Global Directory

  • HVAC Equipment
    • Johnson ControlsJCI logo
    • YORKyork-process-system-logo
    • Championchampion
    • ColemanColeman logo
    • EnvirotecEnviro-Tec logo
    • LuxaireLuxaire Heating & Cooling logo
    • Miller-Picking
    • Pace
    • QuantechQuantech logo
    • Silent-AireSilentAire Logo
    • TempmasterTempMaster logo
    • TriatekTriatek logo
  • Industrial Refrigeration
    • YORKyork-process-system-logo
    • FrickFrick Industrial Refrigeration logo
    • M&M Carnot
    • SabroeSabroe logo
    • York Process Systemsyork-process-system-logo
  • Digital Solutions
    • OpenBlueOpenBlue Logo
    • FM:Systems
  • Building Automation and Controls
    • Johnson ControlsJCI logo
    • MetasysMetasys icon
    • Facility Explorerfacility explorer
    • EasyIOeasyio text
    • VerasysVerasys logo
    • BCProAnsul logo
    • PENNpenn
  • Retail Solutions
    • Sensormatic
  • Fire Suppression
    • Tyco Firetyco
    • AnsulAnsul
    • ChemguardChemguard logo
    • SkumSkum logo
    • HygoodHygood logo
    • GrinnellGrinell logo
    • SprinkCADSprinkCAD logo
    • Pyro ChemPyro-Chem logo
    • AquaMistaquamist_logo
  • Fire Detection
    • AutocallAnsul logo
    • FireClassFireClass logo
    • SimplexSimplex logo
    • ZettlerZettler logo
    • VigilantVigilant logo
    • DBEDBE written on a white background
  • Security
    • American DynamicsAmerican Dynamics Logo
    • DSCDSC logo
    • ExacqExacq logo
    • IllustraIllustra Blue logo
    • KantechKantech logo
    • IQIQ logo
    • Software HouseSoftware House logo
    • Bentel Security Bentel logo
    • CEM SystemsCEM Systems  logo
    • CloudvueCloudvue logo
    • SESSES Logo Image
    • VisonicVisonic logo
JCI Logo
  • Products & Solutions
    Products & Solutions
    • Sprinklers, Nozzles & Accessories
      Sprinklers, Nozzles & Accessories
      • Sprinklers Nozzles Accessories
      • Standard Coverage
      • Nozzles
      • Dry
      • Extended Coverage
      • Sprinkler Accessories
      • Special Application
      • Storage
      • Residential
    • Valves, Devices, & Components
      Valves, Devices, & Components
      • Valves Devices and Components
      • Air Maintenance Devices
      • System Components
      • Dry System Valves
      • Accelerators
      • Deluge and Preaction Valves and Components
      • General Purpose Valves
      • Wet System Valves and Components
      • Fire Sprinkler Switches
    • Fire Grooved
    • Corrosion Solutions
    • Antifreeze
    • Flexible Hose Assemblies and Components
    • MLC-S Pipe System
      MLC-S Pipe System
      • MLC-S Pipe System
      • Fittings
      • Tools
      • Pipes
      • Casting Cup
    • Performance Based Design
      Performance Based Design
      • Performance Based Design
      • EAS-1
      • Quell or Vanquish
    • Smart Prefabricated Solutions
  • Services and Support
    Services and Support
    • Design Services
      Design Services
      • Design Services
      • CAD Files
      • Revit Files
      • Fluid Delivery Time (FDT) Calculation Request Form
    • Training
  • Resources
    Resources
    • Resources Library
    • Technical Datasheets
    • Tech Data Update Summaries
    • Global Fire Sprinkler Guide
    • Regional Product Catalogs
    • Americas Price Book
    • Terms and Conditions
  • Insights
Search
Contact Us
  1. Tyco-Fire
  2. Products and Solutions
  3. Corrosion Solutions
  4. TVC-2 & TVC-6 Advanced Vent Controller
TVC-6 product image
TVC-6 product image
TVC-6 product image
TVC-6 product image
  • TVC-6 thumb image
  • TVC-6 thumb image
  • TVC-6 thumb image
  • TVC-6 thumb image

TVC-2 & TVC-6 Advanced Vent Controller

Automatic Venting and Monitoring

System Type Dry, Preaction
Product Type Monitoring - Corrosion & Gas Concentration
Maximum Tube Length 350 ft (107 m) each zone
Vent Sample Connection 5/32 in. (4 mm) push-connect flexible plastic tube quick connectors
Back to Top

TVC-2 & TVC-6 Advanced Vent Controller

  • Overview
  • Features & Benefits
  • Related Products
  • Specifications
  • Technical Resources
    Contact Us

    System Data at Your Fingertips

    An advanced vent controller provides automatic oxygen venting and monitoring of nitrogen/oxygen concentration levels within each dry/preaction fire sprinkler system. Tyco offers two models: the TVC-2 and the TVC-6. One TVC-2 can control and monitor up to two (2) separate fire sprinkler systems, while the TVC-6 works with up to six (6) systems. The system can be easily monitored via the Human Machine Interface (HMI) display. The screen allows easy access to operation, maintenance, diagnostics and stored historical data.
    System Data at Your Fingertips

    Features

    • Mounts to a wall inside the sprinkler valve room
    • Interactive LCD touchscreen display
    • Simplified troubleshooting with data logging and historical trends by zone
    • Vent can be installed on the riser thanks to nitrogen generator fill-and-purge breathing method
    • Provides pressure and nitrogen purity monitoring for up to two (TVC-2) or six (TVC-6) dry or pre-action systems (previously required one per system)
    • Automated leak rate checks by zone

    Benefits

    Reduced Equipment Footprint
    Reduced Equipment Footprint

    Unique technology eliminates the need for a nitrogen tank or refrigerated air dryer.

    No Remote Equipment
    No Remote Equipment

    Install the vent directly on the riser — no vents are needed at far points of the system.

    Minimize Business Interruption
    Minimize Business Interruption

    System leaks due to corrosion can lead to costly downtime — reducing corrosion helps keep systems healthy and operational.

    Data At Your Fingertips
    Data At Your Fingertips

    Instant access to historical data simplifies diagnostics to help keep systems operational.

    Technical Specification

    Power Supply 120-240VAC/Single phase/50-60Hz, 0.5A Vent Sample Connection 5/32 in. (4 mm) push-connect flexible plastic tube quick connectors
    Temperature Rating 32°F to 122°F (0°C to 50°C) Maximum Tube Length 350 ft (107 m) each zone

    Technical Resources

    Document Name
    Description
    Language
    Resource Type

    Brochure

    Tyco-NG-2-Corrosion-Solutions-Brochure_FS2401016 (English)

    Corrosion solutions for fire sprinkler systems

    English Brochure
    View

    Flyer

    FS2402004_Tyco-NG-2-and-TVC-6-Solution-Brief-US-DIGITAL (English)

    Advanced Vent Controller Solution Brief Flyer

    English Flyer
    View

    Data Sheet

    TFP1260_01_2024 (English)

    Model TVC-2 and TVC-6 Advanced Vent Controllers – TFP1260 (English)

    English Data Sheet
    View

    Installation Guide

    TFP1279_01_2024 (English)

    Model TVC-2 and TVC-6 Advanced Vent Controllers – TFP1279 (English)

    English Installation Guide
    View

    Data Sheet

    TFP1255 Technical Data Sheet (English)

    NG-2 Nitrogen Generator, Standalone – TFP1255 (English)

    English Data Sheet
    View

    Installation Guide

    TFP1278 System Installation Manual (English)

    NG-2 Nitrogen Generator, Standalone – TFP1278 (English)

    English Installation Guide
    View

    Quick Start Guide

    TFP1280_09_2023 (English)

    NG-2 Nitrogen Generator – TFP1280 (English)

    English Quick Start Guide
    View

    Brochure

    Preaction System Components (English)

    Overview of DV-5A valve and key preaction trim components, as well as NG-2 nitrogen generators to avoid corrosion issues

    English Brochure
    View
    No resource found for selected filter

    Back

    Next

    Looking for more Resources
    A laptop on a desk with a finger pointing at a screen

    SprinkCAD Software Suite 

    Save time and ensure quality with the SprinkCAD software suite. Developed to offer fire sprinkler system designers a powerful set of digital tools to create precise solutions. 

    Learn about our all-in-one software package
    Contact Us
    • Antifreeze
    • Corrosion Solutions
    • CPVC
    • Fire Grooved
    • Flexible Hose Assemblies and Components
    • MLC-S Pipe System
    • Performance Based Design
    • Sprinklers, Nozzles and Accessories
    • Valves, Devices, and Components
    • Technical Datasheets
    • Design Files
    • Tech Data Update Summaries
    • Regional Product Catalogs
    • Americas Price Book
    • Insights
    • WARNING: Cancer & Reproductive Harm
    • Regulatory & Health Warnings
    • SVHC statement - CPVC products containing UV-238
    Tyco logo
    Connect With Us
    • LinkedIn logo
    • Twitter X logo
    • YouTube Play logo
    JCI Logo
    © 2025 Johnson Controls. All Rights Reserved.
    • JohnsonControls.com
    • Privacy
    • Legal
    • Terms and Conditions