Page 21 - Tyco-Sprinkler-Application-Chart-Desktop
P. 21

  Special
Notes
(1) Refer to the Technical Data Sheet for specific information. All versions of a sprinkler may not be listed or approved.
(2) Sprinkler Finish Legend (applies to cover plate only for concealed type sprinklers):
(3) Response Legend: SR = Standard Response QR = Quick Response FR = Fast Response
(4) Sprinkler Orientation: EC - Extended Coverage
ESFR - Early Supression Fast Response Opt. - Optimised
(5) Refer to the Technical Datasheet for specific information about ISO Thread availability
Model (1)
TY-B TY-B TY-B TY-B TY-B TY-B TY-B TY-B TY-B TY-B TY-B TY-B TY-B TY-B TY-B TY-B TY-B TY-B
Sprinkler Response Orientation (3)
Part (5) No.
Approvals (1)
(Alternate Materials of Construction)
GW = Grey White (RAL 9002) L = Lead Coating
JB = Jet Black (RAL 9005)
SS = Stainless Steel
W = Wax Coating
Wh = Signal White (RAL 9003) WOL = Wax Coating over Lead X = Custom Color
B =Brass
BB = Bright Brass Bl = Black
C = Chrome Plated
Temperature °F (1)
135, 155, 175, 200, 286, 360
135, 155, 175, 200, 286, 360
135, 155, 175, 200, 286, 360
135, 155, 175, 200, 286, 360
135, 155, 175, 200, 286, 360
135, 155, 175, 200, 286, 360
135, 155, 175, 200, 286, 360
135, 155, 175, 200, 286, 360
135, 155, 175, 200, 286, 360
135, 155, 175, 200, 286, 360
135, 155, 175, 200, 286, 360
135, 155, 175, 200, 286, 360
135, 155, 175, 200, 286, 360
135, 155, 175, 200, 286, 360
135, 155, 175, 200, 286, 360
135, 155, 175, 200, 286, 360
135, 155, 175, 200, 286, 360
135, 155, 175, 200, 286, 360
135, 155, 175, 200, 286 135, 155, 175, 200, 286 135, 155, 175, 200, 286
               Sprinkler
Identification
Number (SIN)                   bar1/2     psi1/2
Operating Element
5 mm Bulb 5 mm Bulb 5 mm Bulb 5 mm Bulb 5 mm Bulb 5 mm Bulb 5 mm Bulb 5 mm Bulb 5 mm Bulb 5 mm Bulb 5 mm Bulb 5 mm Bulb 5 mm Bulb 5 mm Bulb 5 mm Bulb 5 mm Bulb 5 mm Bulb 5 mm Bulb 3 mm Bulb 3 mm Bulb 3 mm Bulb
Sprinkler Finish (1,2)
Stainless Steel Stainless Steel Stainless Steel Stainless Steel Stainless Steel Stainless Steel Stainless Steel Stainless Steel
SMO
(254 Duplex SS)
SMO
(254 Duplex SS)
SMO
(254 Duplex SS)
SMO
(254 Duplex SS)
SMO
(254 Duplex SS)
Titanium Titanium Titanium Titanium Titanium Stainless Steel Stainless Steel Stainless Steel
Recessed Wrench Wrench
K Factor
Thread Data   Base
Max. Pressure bar PSI 12.1 175 12.1 175 12.1 175 12.1 175 12.1 175 12.1 175 12.1 175 12.1 175 12.1 175 12.1 175 12.1 175 12.1 175 12.1 175 12.1 175 12.1 175 12.1 175 12.1 175 12.1 175 12.1 175 12.1 175 12.1 175
Recessed Escutcheon (1)
           LPM/ GPM/
Size Sheet
                           TY8191 TY8291 TY9191 TY9291 TY8691 TY9691 TY8391 TY8491 TY8192 TY8292 TY8692 TY8392 TY8492 TY8193 TY8293 TY8693 TY8393 TY8493
Upright SR (Stainless Steel)
Pendent SR (Stainless Steel)
Upright SR (Stainless Steel)
Pendent (Stainless SR Steel)
Conventional SR (Stainless Steel)
Conventional SR (Stainless Steel)
80.6 5.6 80.6 5.6 115.2 8.0 115.2 8.0 80.6 5.6 115.2 8.0
1/2" TFP680 1/2" TFP680 3/4" TFP680 3/4" TFP680 1/2" TFP680 3/4" TFP680 1/2" TFP680 1/2" TFP680 1/2" TFP680 1/2" TFP680 1/2" TFP680 1/2" TFP680 1/2" TFP680 1/2" TFP680 1/2" TFP680 1/2" TFP680 1/2" TFP680 1/2" TFP680 1/2" TFP680 1/2" TFP680 3/4" TFP680
57-570 57-571 57-590 57-591 57-573 57-593 57-578 57-575 57-570 57-571 57-573 57-578 57-575 57-570 57-571 57-573 57-578 57-575 57-370 57-371 57-390
UL, C-UL, W6 LPCB, Lloyds
                                   UL, C-UL, LPCB, Lloyds
W6 W7 YES
                                   UL, C-UL, W6 LPCB, Lloyds
LPCB, Lloyds W6
                                   UL, C-UL, LPCB, Lloyds
W6 W7 YES LPCB, Lloyds W6
                                                                                                         Horizontal Sidewall (SS)
Vertical Sidewall (SS)
Upright (SMO)
Pendent (SMO)
Conventional (SMO)
Horizontal Sidewall (SMO)
Vertical Sidewall (SMO)
Upright (Titanium)
Pendent (Titanium)
Conventional (Titanium)
Horizontal Sidewall (Titanium)
Vertical Sidewall (Titanium)
SR 80.6 5.6 SR 80.6 5.6 SR 80.6 5.6 SR 80.6 5.6 SR 80.6 5.6 SR 80.6 5.6 SR 80.6 5.6 SR 80.6 5.6 SR 80.6 5.6 SR 80.6 5.6 SR 80.6 5.6 SR 80.6 5.6
LPCB, Lloyds
LPCB, Lloyds W6 LPCB, Lloyds W6
LPCB, Lloyds
LPCB, Lloyds W6
W6 W7 YES
                                                                                                         W6 W7 YES
                                                                      LPCB, Lloyds
LPCB, Lloyds W6 LPCB, Lloyds W6
W6 W7 YES
                                                                                                         LPCB, Lloyds
LPCB, Lloyds W6
W6 W7 YES
                                                                      LPCB, Lloyds
W6 W7 YES
                                                                      TY-FRB TY8181
TY-FRB TY8281
TY-FRB TY9181
(continued on next page)
Upright QR 80.6 5.6 (Stainless Steel)
Pendent QR 80.6 5.6 (Stainless Steel)
LPCB, Lloyds W6
UL, C-UL, W6 LPCB, Lloyds
                                   UL, C-UL, LPCB, Lloyds
W6 W7 YES
                                   www.tyco-fire.com
Upright QR (Stainless Steel)
115.2 8.0
UL, C-UL, W6 LPCB, Lloyds
  SPECIAL
(ALTERNATE MATERIALS OF CONSTRUCTION)
   19   20   21   22   23