Page 5 - Fire Suppression General Products Catalog, Automatic Sprinklers, System Valves and Devices, Piping and Electrical Products
P. 5

 www.tyco-fire.com
 TY-B
Upright, Pendent, & Recessed Pendent
Standard Spray Sprinklers
     K Factor
K=2.8 (40,3) • K=5.6 (80,6) • K=8.0 (115,2)
  Thread Size
1⁄2" NPT • 3⁄4" NPT
    Approvals
K=2.8 – UL, C-UL, FM, NYC
K=5.6 – UL, C-UL, FM, CE, VdS
K=8.0 – UL, C-UL, FM, NYC, LPCB, VdS
   135°F (57°C), 155°F (68°C), 175°F (79°C), 200°F (93°C), 286°F (141°C), 360°F (182°C), Open (TY4151 & TY4251)
 Temperature
   Escutcheon
 All hazard • 5 mm bulb • Small frame, narrow profile bulb • Discharges a hemispherical water spray pattern in the area beneath the sprinkler • Designed for use in light, ordinary, or extra hazard, commercial occupancies such as banks, hotels, shopping malls, factories, refineries, chemical plants, etc.
    Horizontal, Recessed Horizontal Sidewall & Vertical Sidewall
Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.
K=5.6 – Style 15, Style 20 K=8.0 – Style 10, Style 40
   Escutcheon Finish
Signal White, Pure White, Jet Black, Chrome Plated, Natural Brass
   Sprinkler Finish
Natural Brass, Chrome Plated, Pure White,
Signal White, Jet Black, Poly-Stainless, Lead Coated, Wax Coated, Wax over Lead Coated
   SIN
TY1151, TY1251, TY315, TY325, TY4151, TY4251, TY4851, TY4951
   Wrench Type
W-TYPE 6 / W-TYPE 7 (for recessed escutcheons)
  Tech Data Sheet
K=2.8 & K=8.0 – TFP151 / K=5.6 – TFP152
      K Factor
K=5.6 (80,6)
  Thread Size
1⁄2" NPT
   Approvals
UL, C-UL, FM, NYC, LPCB
   Temperature
135°F (57°C), 155°F (68°C), 175°F (79°C), 200°F (93°C), 286°F (141°C), 360°F (182°C), Open (HSW TY3351)
     Escutcheon
Style 10
   Escutcheon Finish
Signal White, Pure White, Jet Black, Chrome Plated, Natural Brass
   Sprinkler Finish
Natural Brass, Chrome Plated, Pure White,
Signal White, Jet Black, Poly-Stainless, Lead Coated, Wax Coated, Wax over Lead Coated
   SIN
TY3351, TY3451
  Wrench Type
 Tech Data Sheet
Light hazard/Ordinary hazard • 5 mm bulb • Small frame • Unique deflector design of the horizontal sidewall sprinkler results in smaller profile • Designed for installation along a wall or the side of a beam just beneath a smooth ceiling • Water discharge is directed primarily outward and downward in a quarter spherical pattern • Sidewall sprinklers are often used in lieu of standard pendent or upright sprinklers due to building construction, economic considerations, or aesthetics • Special deflector on the vertical sidewall sprinkler allows it to be installed in either a pendent or upright position
W-TYPE 6 / W-TYPE 7 (for recessed escutcheons)
 TFP161
          5














































   3   4   5   6   7