Electrical Devices
Nitrogen Generators
Potter IntelliGen® Nitrogen Generators
Potter’s IntelliGen® Series of Nitrogen Generators are specifically designed to generate on-site, 98%+ purity nitrogen for use in fire protection sprinkler systems. When used as a supervisory gas in fire sprinkler systems, nitrogen slows corrosion, improves the life of your system, and lowers maintenance costs.
The Potter IntelliGen® Series utilizes nitrogen membrane technology for gas separation. Nitrogen membranes are highly effective and a cost-conscious way of producing on- site nitrogen. Acting as a gas filter, the nitrogen membrane separates the oxygen and water vapor molecules in the air from the nitrogen molecules. The high-purity nitrogen gas is then piped through the air maintenance device and into the fire protection system. As the system fills with nitrogen, the remaining oxygen molecules in the fire protection system are exhausted through a separate purge valve.
All systems are ready to be connected to a new or existing fire sprinkler system, and include an integrated air compressor, nitrogen membrane, all air filtration equipment, tanks and the patent-pending Potter IntelliGen® Controller. Each unit is designed to be turned on and walk away. The built-in monitoring capabilities will make corrections and alert the user to any necessary changes. Alerts and notifications can be viewed locally or online via the Potter IntelliViewTM website.
Tech Data Sheet
Contact Tyco for details
Potter’s IntelliGen Controller (Patent Pending) •
Fully automates the air and nitrogen fill procedure
• Advanced leak rate detection • Integrated Bypass alarm • Web Enabled – system can be monitored anywhere there is internet connectivity • Automatically emails trouble alerts and maintenance reminders • Includes all air compressors, tanks, filters, relief valves, coolers, automatic drains, and gauges
Unit Type (Shipping)
Model #
* Largest Riser Fill (gal)
** Max
Total System Capacity (gal)
Compressor Type/HP
Air Tank (Gal.)
Nitrogen Tank (Gal.)
Wall Mount (1 Pallet)
INS-100
160
675
Oil-Less, 1/4 HP
--
10
INS-250
300
1000
Oil-Less, 1/2 HP
--
10
Integrated (1 Pallet)
INS-500
500
1850
Oil-Less, 1 HP
20
20
INS-1000
1000
3400
Oil-Less, 2 HP
20
20
Modular (3 Pallets)
INS-1500
2000
6200
Lubricated, 7.5 HP
80
60
INS-2000
2400
12000
Lubricated, 7.5 HP
80
60
INS-2500
2400
24000
Lubricated, 7.5 HP
80
120
* At 40 PSI
** Assuming new system leak rate of 1.5 PSI per 24 hours
Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.