Page 99 - Fire Suppression General Products Catalog, Automatic Sprinklers, System Valves and Devices, Piping and Electrical Products
P. 99

 www.tyco-fire.com
 CPVC
Back-to-Back Fittings
CPVC to Copper Fitting
CPVC Hangers & SHB1 Head Set
CPVC Supplies
Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.
CPVC Pipe & Threaded Fittings
      Sizes
DN20 thru DN80 (3⁄4" thru 3")
  Approvals
UL, C-UL Listed & FM,MEA, NSF, & LPCB Approved
  Rated Pressure
Maximum Temperature Rating
12,1 bar (175 psi)
   65°C (150°F).
  Tech Data Sheet
TFP1915 and
Installation Handbook - IH-1900
   Included in the Tyco line of BLAZEMASTER® CPVC products • Allows two sidewall sprinklers to be piped from one fitting • Ideal when the CPVC piping is located in a 3-1⁄2" (2" x 4") vertical wall, eliminating the need for extra nipples, fittings and sprinkler head adapters typically associated with supplying two rooms with the same pipe • Specially designed and dimensioned to enable the sidewall sprinklers to be recessed with 1⁄2" or 5⁄8" sheet-rock wall covering
       Sizes
DN20 thru DN50 (3⁄4" thru 2" )
   Approvals
UL, C-UL Listed & FM,MEA, NSF, & LPCB Approved
  Rated Pressure
12,1 bar (175 psi)
   Maximum Temperature Rating
65°C (150°F).
   Tech Data Sheet
TFP1915 and
Installation Handbook - IH-1900
   Transition to BLAZEMASTER pipe from traditional copper tube for plumbing services • Transition to steel or BLAZEMASTER
CPVC Fire Sprinkler System piping from traditional copper tube for plumbing services is fast, easy, and readily available in the most complete fire sprinkler package in the industry
     Sizes
3⁄4" thru 1" NPT
     Approvals
Tech Data Sheet
UL Listed
   Material
Galvanized aluminum, 20 gauge
   TFP1920 and
Installation Handbook - IH-1900
   “No Block Hanger" is a two hole strap that eliminates blocking to the beam when hanging CPVC pipe • The TYCO CPVC Hanger Head Set Model SHB1 offers a time saving installation method for proper placement of an automatic sprinkler before the ceiling is installed. • Positions the face of the pipe 1-1⁄2" off the face of the joist • Provides vertical restraint, eliminating need for additional hangers
        Tech Data Sheet
TFP-600 One Step Solvent Cement (TFP1994) and CPVC Installation Handbook (IH-1900)
   One-Step CPVC Cement specifically formulated for use with BlazeMaster® pipe and fittings • BLAZEMASTER Caulk and Walk® Firestop
 www.tyco-fire.com 99