Page 68 - Fire Suppression General Products Catalog, Automatic Sprinklers, System Valves and Devices, Piping and Electrical Products
P. 68

 Fire Suppression General Products Catalog
 Wet System Valves & Devices
RSV-1
Residential Shutoff Valve
      Size Range
Maximum Working Pressure
NFPA 13D - DN25 (1")
NFPA 13R or NFPA 12D - DN50 (2")
     Resi-Riser
Residential
Approvals
Maximum Working Pressure
UL, C-UL, & NSF-61
12,1 bar (175 psi)
  System
For use in residential sprinkler systems
  End Connection
Thread x Thread
  Tech Data Sheet
TFP980
   During the design of a residential sprinkler system, domestic water use should be taken into consideration unless the domestic supply can be stopped when a sprinkler operates • When a sprinkler operates, water supply is automatically diverted from the domestic system to the sprinkler system • Eliminates the need for pumps, pressurized storage tanks, or electrically operated domestic shutoff valves • Valve automatically resets after the fire protection system is returned to normal service
        Size Range
DN25 thru DN50 (1" thru 2")
    WMA-1
Water Motor Alarm
12,1 bar (175 psi)
  System
For use in residential sprinkler systems
  End Connection
Thread x Thread
  Tech Data Sheet
Compact, pre-assembled, ready to install sprinkler riser • Brass construction for use in potable water supply • Integral test and drain assembly, flow switch with retard mechanism, 20,7 bar (300 psi) gauge, and check valve • Compact size allows for easy installation between 50-100 mm (2" x 4") studs • Molded mounting points allow for fast and easy left or right hand installation • Available with or without pressure relief valve or flow switch retard mechanism features
Contact Tyco for details
              Size Range
Maximum Working Pressure
Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.
68
NFPA 13D - DN25 (1")
NFPA 13R or NFPA 12D - DN50 (2")
  Approvals
UL, ULC Listed & FM, VdS, & LPCB Approved
  20,7 bar (300 psi)
For use in a wet type automatic sprinkler system riser
  System
  Tech Data Sheet
TFP921
   Hydraulically operated outdoor alarm for use with appropriate fire protection system valves (alarm, dry, deluge) • Supplied by dedicated outlet in valve trim line or retard chamber • Uses energy-efficient lightweight impeller design capable of producing very high sound level • Corrosion-resistant aluminum alloy gong, gong-mount, and water motor housing • Furnished with approved 20mm (3⁄4") Y-strainer for use in alarm line
    