Page 6 - Fire Suppression General Products Catalog, Automatic Sprinklers, System Valves and Devices, Piping and Electrical Products
P. 6

 Fire Suppression General Products Catalog
 Standard Spray Sprinklers
TY-FRB
Upright, Pendent, & Recessed Pendent
     Light hazard/Ordinary hazard • 3 mm bulb • Small frame and narrow profile bulb enhance appearance • Hemispherical water spray pattern in the area beneath the sprinkler • Designed for use in commercial occupancies such as banks, hotels, and shopping malls.
K=2.8 (40,3) • K=4.2 (60,5) • K=5.6 (80,6) • K=8.0 (115,2)
   Thread Size
1⁄2" NPT • 3⁄4" NPT
   Approvals
K=2.8 – UL, C-UL, FM, NYC
K=4.2 – UL, C-UL
K=5.6 – UL, C-UL, FM, CE, VdS
K=8.0 – UL, C-UL, FM, NYC, LPCB, VdS
   Temperature
57°C (135°F), 68°C (155°F), 79°C (175°F), 93°C (200°F), 141°C (286°F)
   Escutcheon
K=2.8, K=4.2 & K=8.0 – Style 10 • Style 20 • Style 30 • Style 40
K=5.6 – Style 15 • Style 20
    Horizontal, Recessed Horizontal Sidewall & Vertical Sidewall
K Factor
Escutcheon Finish
Signal White, Pure White, Jet Black, Chrome Plated, Natural Brass
   Sprinkler Finish
Natural Brass, Chrome Plated, Pure White,
Signal White, Jet Black, Poly-Stainless, Lead Coated
   SIN
TY313, TY323, TY1131, TY1231, TY2131, TY2231, TY3131, TY3231, TY4131, TY4231, TY4831, TY4931
   Wrench Type
W-TYPE 6 / W-TYPE 7 (for recessed escutcheons)
  Tech Data Sheet
K=2.8 thru K=8.0 – TFP171, K=5.6 – TFP172
           K Factor
K=5.6 (80,6)
  Thread Size
1⁄2" NPT
    Approvals
UL, C-UL, FM, NYC, LPCB
   Temperature
57°C (135°F), 68°C (155°F), 79°C (175°F), 93°C (200°F), 141°C (286°F)
   Escutcheon
Style 10 • Style 20
   Escutcheon Finish
Signal White, Pure White, Jet Black, Chrome Plated, Brass Plated
    Sprinkler Finish
Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.
6
Natural Brass, Chrome Plated, Pure White,
Signal White, Jet Black, Poly-Stainless, Lead Coated
   SIN
 Tech Data Sheet
Light hazard/Ordinary hazard • 3 mm bulb • Designed for use in applications where aesthetics must be considered or where building construction makes the installation of standard pendent or upright sprinklers impractical • Vertical sidewall sprinkler can be installed in either the pendent or upright position along a wall or the side of a beam and just below a smooth ceiling
TY3331, TY3431
  Wrench Type
W-TYPE 6 / W-TYPE 7 (for recessed escutcheons)
 TFP176
      