 Special Application Sprinklers
TY-B & TY-FRB (Alternate Materials Of Construction)
Upright & Pendent Sprinklers
     K Factor
TY-B: 5 mm diameter heat sensitive glass bulb, standard response • TY-FRB: 3 mm diameter heat sensitive glass bulb, quick response • Corrosion resistant, standard coverage spray sprinklers designed for use in commercial occupancies where corrosive atmospheres may exist • Alternate materials of construction (Stainless Steel, SMO, or Titanium) are utilized to extend the life of a sprinkler beyond that which might be expected of copper alloy sprinklers exposed to corrosive atmospheres, (SMO = stainless- molybdenum alloyed)
K=5.6 (80,6) • K=8.0 (115,2)
  Thread Size
1⁄2" NPT • 3⁄4" NPT
      Vertical, Horizontal & Recessed Horizontal Sidewall Sprinklers
Approvals
Temperature
UL, C-UL, LPCB, Lloyds
 57°C/135°F, 68°C/155°F, 79°C/175°F, 93°C/200°F, 141°C/286°F, 182°C/360°F
   Escutcheon Style
Style 10 • Style 40
   Sprinkler Finish
Stainless Steel, SMO, Titanium
   SIN
Refer to Tech Data Sheet for SIN Numbers
   Wrench Type
W-TYPE 6, W-Type 7 (For recessed escutcheons)
  Tech Data Sheet
TFP680
          K Factor
K=5.6 (80,6)
   Thread Size
1⁄2" NPT
   Approvals
UL, C-UL, LPCB
   Temperature
57°C/135°F, 68°C/155°F, 79°C/175°F, 93°C/200°F, 141°C/286°F, 182°C/360°F
   Escutcheon Style
Style 10
   Sprinkler Finish
Stainless Steel, SMO, Titanium
    SIN
Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.
Refer to Tech Data Sheet for SIN Numbers
   Wrench Type
TY-B: 5 mm diameter heat sensitive glass bulb, standard response • TY-FRB: 3 mm diameter heat sensitive glass bulb, quick response • Corrosion resistant, standard coverage spray sprinklers designed for use in commercial occupancies where corrosive atmospheres may exist • Alternate materials of construction (Stainless Steel, SMO, or Titanium) are utilized to extend the life of a sprinkler beyond that which might be expected of copper alloy sprinklers exposed to corrosive atmospheres (SMO = stainless- molybdenum alloyed)
W-TYPE 6, W-Type 7 (For recessed escutcheons)
  Tech Data Sheet
TFP680