 LFII • NFPA 13 Optimized Sprinklers
The large orifice 6.9 K, 5.8 K and 5.6 K sprinklers are primarily intended for residential use where there is a 0.1 gpm/sq. ft. density NFPA 13 design requirement, and are generally used for installations in excess of four stories. They are optimized for residential applications where this higher water-flow demand is required, and can meet those requirements with less pressure and smaller pipe sizes.
Pendent, Recessed Pendent & Domed Concealed
Rapid Response® Sprinklers
     K Factor
  Thread Size
UL, C-UL, FM, NYC, NSF/ANSI 61
   Temperature
68°C/155°F, 79°C/175°F, 59°C/139°F - Cover Plate
  Escutcheon
Style 30
   Escutcheon & Sprinkler Finish
Natural Brass, Chrome Plated, Pure White, Signal White
   Cover Plate Finish
Pure White, Signal White, Chrome, Custom
    Horizontal & Recessed Horizontal Sidewall Sprinklers
SIN
TY4234
   Wrench Type
W-TYPE 6, W-Type 7 (For recessed escutcheons)
  Tech Data Sheet
TFP408
   3 mm bulb type
Intended for use in the following scenarios:
- wet pipe residential sprinkler systems for one/two-family dwellings and mobile homes per NFPA 13D - wet pipe residential occupancies up to and including four stories in height per NFPA 13R
- wet pipe sprinkler systems for the residential portions of any occupancy per NFPA 13
    K Factor
K=5.8 (83,5)
  Thread Size
1⁄2" NPT
    Approvals
Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.
K=6.9 (99,4)
 3⁄4" NPT
   Approvals
UL, C-UL, FM, NSF/ANSI 61
   Temperature
68°C/155°F, 79°C/175°F
   Escutcheon
Style 20
   Sprinkler Finish
Signal White, Chrome Plated, Natural Brass
   SIN
TY4334
   Wrench Type
W-TYPE 6, W-Type 7 (For recessed escutcheons)
  Tech Data Sheet
TFP417
   3 mm bulb type • Can be used for horizontal and sloped ceilings
Intended for use in the following scenarios:
- wet pipe residential sprinkler systems for one/two-family dwellings and mobile homes per NFPA 13D - wet pipe residential occupancies up to and including four stories in height per NFPA 13R
- wet pipe sprinkler systems for the residential portions of any occupancy per NFPA 13